Key result
Transapical TAVR with the MedLab-KT device is linked to de-novo conduction abnormalities in ~51% of patients.
Why the study?
Cardiac conduction disturbances after transapical TAVR with the MedLab-KT device in the early postoperative period were not well characterized.
Observational (n=80)
No
Answers are grounded in this paper and cite their sources.
Alerts clinicians to monitor for conduction issues with MedLab-KT transapical TAVR; leaves open comparative safety versus other devices.
Aim: to assess cardiac conduction disturbances after transcatheter aortic valve replacement (TAVR) with the “MedLab-KT” device in early postoperative period. Methods. The study comprised 80 patients (mean age 72,4±5,1 years; 42,5% males) undergoing successful TAVR with the “MedLab-KT”. Before operation, all patients were evaluated with 12-lead ECG and 24-hour Holter monitoring, transthoracic and transesophageal echocardiography, computed tomography, coronarography. In 29 (36,3%) patients cardiac conduction abnormalities were detected before operation: 1st degree atrioventricular (AV) block was found in 17 patients, including concomitant left anterior hemiblock (LAH) in 7 patients, and right bundle branch block (RBBB) in 3 (LAH+RBBB). Second degree AV-block type 1 was found in 1 patient. LAH – in 2, RBBB – in 5, and left bundle branch block (LBBB) – in 4. Post-operative follow-up was limited to hospital stay (13,4±7,4 days). Results. De-novo conduction abnormalities (reversible and irreversible) were detected in 41 patients (51,3%). Post-TAVR complete AV-block was found in 6 (7,5%) patients, and required temporal pacing. In 4 of those patients AV-block was transient and resolved within 1 day. In 2 (2,5%) patients permanent pacing was required due to irreversible distal AV-block. In one case AV-block developed 2 days after TAVR in a patient with pre-existent 1st degree AV-block in combination with LAH+RBBB. Another patient developed complete AV-block at 3d day after TAVR; in this case there was pre-existent 1st degree AV-block plus LAH. Persistent interventricular block was found in 35 patients: complete LBBB - in 17 patients and complete RBBB – in 1 patient. There were no statistically significant predictors of conduction disturbance development following TAVR.
No takes yet. Share an insight, caveat, or question.
Popylkova et al. (2019) conducted an observational in Aortic stenosis (n=80). Transapical TAVR with MedLab-KT device was evaluated on De-novo cardiac conduction abnormalities (reversible and irreversible).
Synapse has enriched 10 related papers. Consider them for comparative context: