Key result
Adding pacing to ATP provocation cuts atrial tachyarrhythmia recurrence ~55% after pulmonary vein isolation.
Why the study?
It was uncertain whether ATP provocation and pacing are interchangeable or complementary endpoints for ablation durability in paroxysmal atrial fibrillation after CPVI.
RCT (n=214)
Randomly divided
Answers are grounded in this paper and cite their sources.
Using both ATP provocation and pacing may identify additional gaps after CPVI; leaves open whether combined testing improves durable isolation in randomized trials.
INTRODUCTION: Adenosine triphosphate (ATP)-provoked dormant conduction (DC) and pacing for unexcitability are used to identify conduction gaps along the ablation lines after circumferential pulmonary vein isolation (CPVI). We aim to determine whether ATP provocation and pacing are interchangeable as endpoints for ablation of paroxysmal atrial fibrillation (PAF). METHODS AND RESULTS: A total of 107 patients with PAF were randomly divided into two groups after completion of CPVI. In group I (A-P group, n = 53), ATP was administered first. If DC was uncovered, additional ablation was performed until ATP tests were negative. Bipolar pacing along the ablation line was performed subsequently. In group II (P-A group, n = 54), the same protocol was used, but the pacing and the ATP tests were performed in the opposite sequence. The 12-month ablation outcomes of all patients were compared with those of a historical control group of 107 patients with PAF in whom only ATP test was performed. Regardless of which test was performed first, the other modality still identified conduction gaps. In group I, pacing maneuvers identified gaps in 49% (n = 26) of patients who had negative ATP tests. In group II, ATP tests uncovered DC in 18.5% (n = 10) of patients in whom pacing identified no gaps. After 12 months, a higher proportion of patients (91.6%) were free from atrial tachyarrhythmias compared with the historical control group (81.3%; P = 0.031). CONCLUSION: Pacing along the ablation lines and ATP provocation are complementary tests for evaluating the durability of CPVI and can lead to better long-term outcomes when used in combination.
No takes yet. Share an insight, caveat, or question.
Zeng et al. (2019) conducted an RCT in Paroxysmal atrial fibrillation (PAF) (n=214). Combination of pacing and ATP provocation vs. ATP provocation alone (historical control) was evaluated on Freedom from atrial tachyarrhythmias (p=0.031). Combining pacing and ATP provocation after pulmonary vein isolation increased 12-month freedom from atrial tachyarrhythmias compared to ATP testing alone.
Synapse has enriched 10 related papers. Consider them for comparative context: