Answers are grounded in this paper and cite their sources.
Water electrolysis is the leading route to green hydrogen, but its separator is never perfect: hydrogen crosses into the oxygen stream and oxygen into the hydrogen stream. A hydrogen–oxygen mixture is flammable above about 4 vol% hydrogen, so cross-over must be monitored continuously; plants shut down at 2 vol%. Its sensors were mostly developed for hydrogen leaks in air, and no review has examined how they perform inside an electrolyser; this review closes that gap. It derives six requirements for a cross-over sensor, assesses seven hydrogen-sensing families and relevant oxygen-sensing principles against them, and finds the market dominated by air-referenced leak detectors, not process analyzers. In a 103-day field study (8,041,007 one-hertz samples), an in-house electrochemical sensor and a commercial analyzer sampling the same gas disagreed by a persistent 1.3–1.5 vol%; only the in-house channel held a stable zero while the plant was idle. A long-term-stability qualification protocol is proposed.
No takes yet. Share an insight, caveat, or question.
Yang et al. (2026) studied this question.