Key result
Sleep apnea in nondippers is linked to ~4-fold higher hs-CRP levels.
Why the study?
Patients with sleep apnea syndrome have increased cardiovascular risk and frequently show a nondipper pattern of systolic blood pressure, but neurohumoral activation and risk factors related to this pattern are not fully understood.
Cross-Sectional (n=121)
Absolute Event Rate: 1.47% vs 0.37%
p-value: p=0.001
May signal heightened inflammatory risk in nondippers warranting apnea evaluation; leaves open whether treating apnea reduces markers or events.
OBJECTIVE: Patients with sleep apnea syndrome have an increased risk of cardiovascular events and frequently show a nondipper pattern (blunted nocturnal decline <10%) of systolic blood pressure. We investigated neurohumoral activation and risk factors in relation to nocturnal blood pressure dipping pattern and sleep apnea syndrome. METHODS: We conducted sleep polysomnography and ambulatory blood pressure monitoring and measured high-sensitivity C-reactive protein, tissue-type plasminogen activator inhibitor-1, and neurohumoral factors in 121 outpatients with suspected sleep apnea syndrome who were classified into four groups on the basis of the presence or the absence of dipping/nondipping and sleep apnea syndrome. RESULTS: Nondippers with sleep apnea syndrome had higher high-sensitivity C-reactive protein (overall P < 0.001), plasminogen activator inhibitor-1 (overall P = 0.004), and aldosterone levels (overall P = 0.010) than any of the other three groups. After adjustment for significant covariates such as age, sex, body mass index, waist circumference, smoking, alcohol drinking, aspirin use, presence of diabetes, and insulin, nondippers with sleep apnea syndrome still had a higher high-sensitivity C-reactive protein level than nondippers without sleep apnea syndrome (geometric mean: 1.47 vs. 0.37 mg/l, P = 0.001). In multiple linear regression analysis controlling for confounding factors related with sleep apnea syndrome, high-sensitivity C-reactive protein was significantly correlated with 3% oxygen desaturation index (P = 0.047). Plasminogen activator inhibitor-1 level was also highest in the nondippers with sleep apnea syndrome but not independent of obesity. Plasminogen activator inhibitor-1 level correlated with insulin (r = 0.32, P = 0.002) and high-sensitivity C-reactive protein levels (r = 0.26, P = 0.005). CONCLUSION: Nondipper status was associated with an increased high-sensitivity C-reactive protein level in patients who also had sleep apnea syndrome but not in those who did not. High-sensitivity C-reactive protein level was closely affected by the desaturation level. Plasminogen activator inhibitor-1 level is also increased in nondippers with sleep apnea syndrome and is related to insulin and high-sensitivity C-reactive protein levels.
No takes yet. Share an insight, caveat, or question.
Ishikawa et al. (2008) conducted a cross-sectional in Suspected sleep apnea syndrome (n=121). Nondipper status with sleep apnea syndrome vs. Nondipper status without sleep apnea syndrome was evaluated on High-sensitivity C-reactive protein level (mg/L) (p=0.001). Nondippers with sleep apnea syndrome had significantly higher high-sensitivity C-reactive protein levels than nondippers without the syndrome (geometric mean 1.47 vs. 0.37 mg/L; P=0.001).
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: