Key result
ELA Chorus pacemaker is associated with successful automatic reprogramming across 427 pacemaker-mediated tachycardias.
Why the study?
Clinical performance and programming features of the new ELA Chorus dual chamber pacemaker required evaluation in patients with various conduction and rhythm disorders.
Observational (n=35)
Answers are grounded in this paper and cite their sources.
May aid PMT management in dual-chamber devices; leaves open outcome benefits and applicability to modern pacemakers.
We evaluated the clinical performance of a new dual chamber pacemaker, ELA Chorus, in 35 patients. This device incorporates linear rate adaptive AV delay (AVDR), rate smoothing, fallback, impedance telemetry, pacemaker mediated tachycardia (PMT) recognition and reprogramming software, intracardiac electrogram displays, autothreshold testing, diagnostic data, battery depletion curves, and laptop computer programming. Mean patient age was 68 years; 18 patients had AV block, six had sinus node dysfunction (one with AV block), nine had carotid sinus hypersensitivity (three with AV block), and two had vagally mediated syncope. At hospital discharge, programming was DDD with a mean low rate of 60 (50-70) beats/min, mean high rate of 126 (120-154) beats/min; AVDR was ON in 21 patients, rate smoothing ON in six patients, fallback ON in six patients, and PMT reprogramming algorithm ON in 27 patients. Pacemaker follow-up involved 500 clinic visits over 14.3 months (1-36). Three patients developed atrial fibrillation, reprogrammed to DDI mode (two patients) or fallback (one patient). Fallback was used 617 times. PMT occurred 427 times in six patients; the PMT algorithm reprogrammed AV delay and postventricular atrial refractory period (PVARP) automatically, a function unique to the Chorus. Intracardiac electrograms and autothreshold testing improved follow-up efficiency. This new dual chamber pacemaker enhances programming flexibility and improves diagnostic accuracy at follow-up.
No takes yet. Share an insight, caveat, or question.
Kutalek et al. (1992) conducted an observational in Indications for pacing including AV block, sinus node dysfunction, carotid sinus hypersensitivity, and vagally mediated syncope (n=35). ELA Chorus dual chamber pacemaker was evaluated on Clinical performance (including pacemaker mediated tachycardia recognition, fallback, and diagnostic accuracy). The ELA Chorus dual chamber pacemaker enhanced programming flexibility and diagnostic accuracy during 14.3 months of follow-up, automatically reprogramming during 427 pacemaker-mediated tachycardias.
Synapse has enriched 10 related papers. Consider them for comparative context: