Novel RISC-V SoC achieves ~96% accuracy for ECG anomaly detection.
Why the study?
Continuous ECG monitoring in wearable biomedical devices requires processing architectures that balance computational simplicity with hardware efficiency.
The proposed silicon-proven System-on-Chip provides a compact, low-power hardware platform for real-time ECG anomaly detection in wearable biomedical devices.
May enable efficient wearable ECG monitoring; extends hardware designs but leaves open clinical validation.
Continuous electrocardiogram (ECG) monitoring in wearable biomedical devices requires processing architectures that balance computational simplicity with hardware efficiency. This paper presents a compact, silicon-proven System-on-Chip (SoC) integrating a PicoRV32 (RV32I) RISC-V processor core with a dedicated multiplierless 1D convolution accelerator for real-time binary ECG anomaly detection. The accelerator implements a hard-wired three-tap Laplacian kernel ([−1,2,−1]) coupled with a programmable threshold comparator. By replacing hardware multipliers with a shift-add-negate tree, the datapath requires O(N) full-adder equivalents for N-bit samples, compared with O(N2) for a multiplier-based 3-tap filter, and executes deterministically in a single clock cycle. The accelerator interfaces with the RISC-V core through a memory-mapped handshake bus. Fabricated in a 180-nm CMOS process, the SoC occupies an active core area of 0.936 mm2 (9373 standard-cell instances at 75.2% density) and was validated on a custom PCB using a UART host interface streaming MIT-BIH Arrhythmia Database records. On five records (10,393 beats) with per-patient threshold calibration, the chip achieves 95.88% Normal/Abnormal accuracy. At 1.8 V and 100 MHz the measured active power is 25.2 mW, and the measured sleep-mode leakage is 44 nW (44 nA at 1.0 V). These results provide a compact, area-efficient ASIC platform for wearable cardiac monitoring, whose power consumption can be further reduced by operating at lower clock frequencies.
No takes yet. Share an insight, caveat, or question.
Le et al. (2026) studied Arrhythmia (ECG anomaly detection) (n=5). PicoRV32-based SoC with 1D convolution accelerator was evaluated on Normal/Abnormal accuracy. A PicoRV32-based SoC with a 1D convolution accelerator achieved 95.88% Normal/Abnormal accuracy for ECG anomaly detection on 10,393 beats from the MIT-BIH Arrhythmia Database.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: