This paper presents a modeling approach to quantify afterpulsing in neutron-irradiated SPADs by combining an established analytical trapping/de-trapping model with trap parameters taken from published defect data and from NIEL displacement-damage scaling, and with the device fields and geometry obtained from numerical device simulation. The model assessment is performed for a 180 nm CMOS SPAD design and the model predicts a 28% increase in afterpulsing probability following exposure to a 1 MeV-neutron equivalent fluence of 4.29 × 10 10 n/cm 2 . The predicted magnitude and the predicted monotonic increase with excess bias are consistent with the afterpulsing levels and bias dependence reported in previous works for CMOS SPADs at comparable displacement-damage levels. A Monte-Carlo uncertainty analysis shows that, although the absolute afterpulsing probability inherits a wide uncertainty from the trap activation energies, the predicted relative increase is robust. The work provides a quantitative framework for predicting afterpulsing in irradiated SPADs, supporting the design of radiation-hardened devices for extreme environments such as space exploration and nuclear instrumentation.
No takes yet. Share an insight, caveat, or question.
Zarei et al. (2026) studied this question.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: