Key result
In a drug-induced porcine failing heart model, increased LV support pressure significantly improved left ventricular stroke volume (coefficient 0.037, p<0.001).
Why the study?
Current advanced heart failure treatments such as cardiac transplantation or blood-contacting pump technology have complications including stroke and bleeding, motivating investigation of alternative support methods.
Effect estimate: Coefficient 0.037
p-value: p=<0.001
Epicardial biventricular augmentation warrants further preclinical testing in HF models; leaves open clinical translation pending human trials.
For treatment of advanced heart failure, current strategies include cardiac transplantation or blood-contacting pump technology associated with complications, including stroke and bleeding. This study investigated an individualized biventricular epicardial augmentation technology in a drug-induced porcine failing heart model. A total of 11 pigs were used, for the assessment of hemodynamics and cardiac function under various conditions of support pressures and support durations (n = 4), to assess device positioning and function by in vivo computer tomographic imaging (n = 3) and to investigate a minimally invasive implantation on the beating heart (n = 4). Support pressures of 20-80 mm Hg gradually augmented cardiac function parameters in this animal model as indicated by increased left ventricular stroke volume, end-systolic pressures, and decreased end-diastolic pressures. Strong evidence was found regarding the necessity of mechanical synchronization of support end with the isovolumetric relaxation phase of the heart. In addition, the customized, self-expandable implant enabled a marker-guided minimally invasive implantation through a 4 cm skin incision using fluoroscopy. Correct positioning was confirmed in computer tomographic images. Continued long-term survival investigations will deliver preclinical evidence for further development of this concept.
No takes yet. Share an insight, caveat, or question.
Jagschies et al. (2017) studied Drug-induced failing heart. Individualized Biventricular Epicardial Augmentation Technology was evaluated on Dependency of left ventricular stroke volume (LVSV) on LV support pressure (Coefficient 0.037, p=<0.001). In a drug-induced porcine failing heart model, increased LV support pressure significantly improved left ventricular stroke volume (coefficient 0.037, p<0.001).
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: