Key result
Intraoperative TEE incidentally detects bilateral lung consolidation during delayed sternal closure after LVAD exchange.
Why the study?
Transesophageal echocardiography often includes lung imaging when aeration is lost, but the significance of static and dynamic air bronchograms in this context is unclear.
Case Report (n=1)
No
Answers are grounded in this paper and cite their sources.
Intraoperative transesophageal echocardiography can incidentally detect bilateral lung consolidation and qualitative static and dynamic air bronchograms, providing immediate complementary pulmonary information that must be interpreted alongside clinical context and conventional imaging.
Transesophageal echocardiography (TEE) is performed primarily for cardiac indications, but the acoustic window frequently includes portions of the lung, particularly once normal aeration is lost. We present the intraoperative TEE findings in a 56-year-old woman with ischemic cardiomyopathy who underwent delayed sternal closure after exchange of a durable left ventricular assist device (LVAD) for pump thrombosis. In addition to the expected assessment of device position, flow profiles, interventricular septal position, and right ventricular systolic function, the examination incidentally demonstrated bilateral lung consolidation containing multiple punctate and branching hyperechoic structures. On qualitative assessment of the recorded clips, some structures appeared relatively stationary, whereas others showed apparent movement, suggestive of static and dynamic air bronchograms. Bronchogram displacement was not measured, and no synchronized respiratory tracing was available to confirm inspiratory timing. The coexistence of these appearances may have reflected heterogeneous regional pulmonary pathology and did not, by itself, establish a single diagnosis. The patient subsequently required reintubation, frequent pulmonary toileting, and tracheostomy. These images illustrate that pulmonary abnormalities may appear within the transesophageal window when TEE is otherwise indicated, while emphasizing the limitations of qualitative assessment of bronchogram motion.
No takes yet. Share an insight, caveat, or question.
Aibek E. Mirrakhimov (2026) conducted a case report in Ischemic cardiomyopathy with durable LVAD undergoing delayed sternal closure after pump exchange for thrombosis (n=1). Intraoperative transesophageal echocardiography (TEE) was evaluated on Incidental detection of bilateral lung consolidation with static and dynamic air bronchograms. Intraoperative TEE incidentally identified bilateral lung consolidation with static and dynamic air bronchograms in a 56-year-old woman undergoing delayed sternal closure after LVAD exchange.
Synapse has enriched 10 related papers. Consider them for comparative context: