Key result
Latex wrap heart isolation eliminates extracardiac conductance distortion to enable accurate open-chest volume measurements.
Why the study?
Current calibration methods for measuring parallel conductance in left ventricular volume measurements are imprecise and impractical in open chest conditions due to frequent changes in parallel conductance.
May improve conductance volumetry accuracy in open-chest models; leaves open clinical translation pending validation.
Modern indices of left ventricular function require accurate measurement of left ventricular volume (LVV). Although conductance catheter (COND) measurements of LVV have been found to be reproducible under steady state conditions in closed chest animals, after median sternotomy, measurements of LVV are subject to exaggerated variation in parallel conductance (alpha Vc) outside of the left ventricle. Current calibration methods for measuring alpha Vc include hypertonic saline injection and quantitative two dimensional echocardiography. Unfortunately, these methods are hampered by imprecision, since frequent changes in alpha Vc in the open chest make recalibration impractical. Accordingly, a latex wrap technique was developed to insulate the left ventricle from extracardiac sources of alpha Vc in the open chest. Anesthetized pigs (n = 5) underwent a median sternotomy with insertion of a 6 French COND-micromanometer combination catheter into the left ventricle. Three conditions were tested: 1) unaltered; 2) metallic retractor outside of the pericardium (metal); and 3) latex wrap between the metal and pericardium. Pressure/COND loops showed that the insulator improved the shape of the loops and decreased alpha Vc, as measured by an echo-area/COND relationship, whereas metal increased alpha Vc and produced artifacts in the loops. In conclusion, electrical isolation eliminates distortion of pressure/COND loops related to extracardiac sources of alpha Vc, therefore allowing for accurate COND measurements in the open chest.
No takes yet. Share an insight, caveat, or question.
Cabreriza et al. (1997) studied left ventricular volume measurement (n=5). Latex wrap technique vs. Unaltered condition and metallic retractor outside of the pericardium was evaluated on Shape of pressure/conductance loops and parallel conductance (alpha Vc). Electrical isolation of the heart using a latex wrap eliminated distortion of pressure/conductance loops related to extracardiac sources, allowing accurate volume measurements in the open chest.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: