Optimal thermal and lighting environments are critical for occupant comfort in office buildings, yet their interactions in open-plan offices remain underexplored in real-world settings. This study presents a year-long field investigation in a representative open-plan office in Wuhan, China, within the hot summer and cold winter (HSCW) climate zone, integrating subjective comfort votes, adaptive behaviors, and objective environmental data (n=3910). Seasonal neutral operative temperatures ranged from 22.7°C to 25.9°C, and neutral illuminances from 345 lx to 397 lx, with comfort ranges spanning 21.5°C–27.4°C and 300 lx–703 lx, respectively. Lighting and thermal factors exhibited dynamic seasonal interactions, influencing adaptive behaviors and comfort perceptions. Illuminance modulated thermal adaptation through passive radiant heat gain, while operative temperature significantly shaped lighting-related adaptations in summer and autumn. Higher temperatures enhanced lighting sensation in spring and summer, but illuminance effects on thermal comfort varied—positive in summer, negative in autumn. Using multi-method cross-validation, this study elucidates lighting-thermal interaction mechanisms, offering evidence-based comfort ranges to guide energy-efficient design and intelligent environmental control in HSCW open-plan offices.