This is the authors' abstract. We don't add key points for this paper.
In this paper, a thermo-optic tuning optical waveguide sensor system based on a cascaded double micro-ring resonator is investigated. The system consists of a micro-ring resonator with the microheater as a reference ring and a micro-ring resonator with removing the upper cladding layers as a sensing ring, combined with a microfluidic control. The refractive index change of the sample is measured by the electric power change of the microheater. The experimental results show that the sensitivity of the thermo-optic tuning is 34.231 W/RIU (refractive index units), and the measurement range is 4.325 × 10−3 RIU, almost eight times larger than that of the cascaded double micro-ring resonator without thermo-optic tuning for the intensity interrogation.
Answers are grounded in this paper and cite their sources.
No takes yet. Share an insight, caveat, or question.
Yang et al. (2020) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: