Answers are grounded in this paper and cite their sources.
Rapid low-ppm detection of toxic and corrosive hydrogen sulfide (H2S) is essential to protect workers and the public. This research presents the synthesis and gas-sensing application of two electroactive poly(amic acid)s (EPAAs): a linear-type (L-EPAA) and a branched-type (B-EPAA). Synthesized via condensation polymerization using electroactive diamine monomers composed of linear and pendant side-chain double-terminal aniline tetramers, their chemical structures, molecular weight, electroactivity, and conductivity were verified using ATR-FTIR, GPC, cyclic voltammetry, and four-point probe testing. To significantly increase the specific surface area, electrospinning technology was employed to fabricate a porous fiber film (B-EPAA-ES). All samples were deposited onto interdigitated electrodes to evaluate their H2S gas sensing properties. Among the tested results, the electrospun B-EPAA-ES film demonstrated the most outstanding performance, exhibiting a 47.4% response to 10 ppm of H2S with a rapid response time of 53.1 s. Moreover, the sensor displayed remarkable reproducibility (CV of 0.2% over three cycles) and the H2S response is unaffected by other gases. Ultimately, the B-EPAA-ES film combines high processability of poly(amic acid), reversible redox properties of side-chain aniline tetramers, and a large specific surface area. This synergistic combination enables highly repeatable H2S detection and the response is unaffected by other gases.
No takes yet. Share an insight, caveat, or question.
Chang et al. (2026) studied this question.