PURPOSE: To describe a modified up-and-over access technique for treatment of iliac artery aneurysms in patients with prior bifurcated stent-grafts for endovascular aneurysm repair (EVAR). TECHNIQUE: This technique uses a coaxial 12-F flexible sheath that is docked with a through-and-through wire into a 7-F sheath advanced from the contralateral femoral approach. This maneuver allows both sheaths to be moved as a unit while maintaining position of the apex of the system as it loops over the flow divider, avoiding damage to or displacing the extant endograft. Once the 12-F sheath is positioned in the iliac limb of the aortic stent-graft and secured in place with the through-and-through wire, the repair is extended into the internal iliac artery using a bridging stent-graft or covered stent introduced via a coaxial sheath. CONCLUSION: The up-and-over technique with a flexible 12-F sheath mated with a 7-F sheath from the opposite side allows bilateral femoral access to be used for iliac branch device placement after prior aortic endograft procedures that create a higher, acutely angled bifurcation. Use of a through-and-through wire and a coaxial sheath for stent delivery creates a very stable platform for intervention.