This is the authors' abstract. We don't add key points for this paper.
In the recent study by Kriege et al. [1], comparing performance of the McGrath™ videolaryngoscope with direct laryngoscopy for rapid sequence intubation in the operating theatre, 94 of 500 patients (19%) in the direct laryngoscopy group had a Cormack and Lehane grade view ≥ 3.; however, study participants had an expected normal airway, direct laryngoscopy was performed under sufficient neuromuscular blockade and external laryngeal manipulations were allowed to improve laryngeal visualisation. Importantly, the incidence of difficult laryngoscopy was significantly higher in this study, compared with their previous work comparing the performance of the McGrath videolaryngoscope with direct laryngoscopy in elective patients with an anticipated normal airway [2]. As the two studies had almost identical research conditions, we are interested to know why there is an approximate 1.4-fold increase in the incidence of difficult laryngoscopy in their latest work. Furthermore, in sample size evaluation, Kriege et al. state that the power calculation assumed first pass success rates of 97% and 92% for the McGrath and direct laryngoscopy groups, respectively. According to the two references cited by them in the power calculation [3, 4], we note that the reported first pass success rate with direct laryngoscopy was only 73.1–78.6%, rather than 92%. The EMMA trial by Kriege et al. comparing the performance of the McGrath videolaryngoscope with direct laryngoscopy in elective patients was completed in May 2019 [2], while this multicentre, randomised controlled trial comparing the two same devices for rapid sequence intubation in the operating theatre was initiated on 24 July 2021 (ClinicalTrials.gov: NCT04794764). It is unclear why Kriege et al. did not use the first-pass success rates of McGrath and direct laryngoscopy from their EMMA trial (94% vs. 71.6%) for sample size evaluation in this subsequent clinical trial comparing the same two devices. We are concerned that using an assumed first-pass success rate of 92% for direct laryngoscopy in this study will have overestimated the performance of direct laryngoscopy and resulted in an inappropriate estimation of a large sample size requiring 500 patients per group. Finally, the actual difference in efficacy between the two studied devices greatly exceeds the assumed value in this study, that is, a 5% absolute between-group difference. Unlike other similar multicentre randomised controlled trials with large sample sizes [5, 6], the design of this study did not include an interim analysis. We believe that trial enrolment would have been stopped in advance by a data and safety monitoring board according to the prespecified stopping criteria if a pre-planned interim analysis had been performed.
Answers are grounded in this paper and cite their sources.
No takes yet. Share an insight, caveat, or question.
Xue et al. (2024) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: