Key result
New cobalt chromium biolimus-eluting stent shows similar 9-month MACE rates to historical control stent.
Why the study?
The first clinical efficacy and safety outcomes of the new thin-strut cobalt chromium biolimus-eluting stent (CoCr-BES) had not been reported in an international multi-centre registry.
Observational (n=400)
Yes
Hazard Ratio: 0.83 (95% CI 0.55–1.26)
Absolute Event Rate: 4.29% vs 4.99%
p-value: p=0.38
May support CoCr-BES use in all-comers; leaves open whether it improves outcomes versus prior platforms in randomized trials.
BACKGROUND: The biolimus-eluting stent (BES) was the first to elute anti-proliferative drug from a biodegradable polymer. In the randomized LEADERS trial, a stainless steel BES showed non-inferior efficacy compared to a sirolimus-eluting stent and a long-term safety advantage. We report the first clinical efficacy and safety outcomes of a new thin-strut cobalt chromium biolimus-eluting stent (CoCr-BES) from an international multi-centre registry. METHODS: We studied 400 all-comer patients with coronary disease receiving CoCr-BES at 12 centres, with follow-up at 9 months and 2 years. The primary endpoint was incidence of major adverse cardiac events (MACE) at 9 months comprising cardiac death, myocardial infarction (MI), and clinically indicated target vessel revascularization (ci-TVR). Key protocol elements were the same as the randomized LEADERS trial to enable a historical control for propensity-matched comparison. RESULTS: Mean patient age was 65 ± 11 years, 19% had diabetes, and 55% presented with unstable angina or MI. On discharge, 96% of patients were on dual antiplatelet therapy (DAPT) and 69% were on DAPT at 9 months. MACE at 9 months occurred in 3.9% of patients, cardiac death in 0.8%, MI in 1.1% and ci-TVR in 2.7%. One patient (0.25%) experienced definite or probable stent thrombosis (ST). A propensity-adjusted comparison showed similar clinical outcomes to the BES arm in the LEADERS trial for the primary endpoint MACE. CONCLUSIONS: The new CoCr-BES showed low rates of MACE, MI, ci-TVR and ST at 9 months, similar to the BES arm in LEADERS.
No takes yet. Share an insight, caveat, or question.
Menown et al. (2020) conducted an observational in Coronary artery disease and acute coronary syndromes (n=400). Cobalt chromium biolimus-eluting stent (CoCr-BES / Biomatrix Alpha™) vs. Stainless steel biolimus-eluting stent (historical control from LEADERS trial) was evaluated on Major adverse cardiac events (MACE) at 9 months (composite of cardiac death, MI, and clinically indicated target vessel revascularization) (HR 0.83, 95% CI 0.55-1.26, p=0.38). The new cobalt chromium biolimus-eluting stent demonstrated a low 4.29% rate of MACE at 9 months, yielding clinical outcomes similar to a propensity-matched historical stainless steel stent control (HR 0.83).
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: