Key result
Angina with normal coronaries is linked to ~0.8-second longer coronary sinus filling time vs controls.
Why the study?
Dysfunction of the coronary microcirculation is considered a factor responsible for symptoms and abnormal stress tests in patients with angina and normal coronaries, but assessment methods are limited.
Observational (n=57)
Absolute Event Rate: 4.25% vs 3.46%
p-value: p=0.001
OBJECTIVE: Dysfunction of the coronary microcirculation is considered as one of the factors responsible for symptoms and abnormal stress tests in patients with angina and normal coronaries (syndrome X). We sought to evaluate the usefulness of coronary sinus filling time (CSFT) to assess coronary microcirculation in this group of patients. METHODS: We compared the CSFT of patients having definite angina or atypical angina with positive treadmill electrocardiography test (angina group), with that of patients undergoing coronary angiogram (CAG) prior to balloon mitral valvuloplasty (control group). During CAG, coronary sinus was visualized in appropriate views and CSFT in seconds was derived from frame count. Thrombolysis In Myocardial Infarction (TIMI) flow grade, corrected TIMI (cTIMI) frame count, TIMI Myocardial Perfusion grade (TMP) were assessed. RESULTS: There were 41 patients in angina group and 16 in control group. Among the angina group 68.8% were females as against 81.8% in the control group. 87.8% (n = 36) had typical angina. Mean CSFT was 4.25 ± 0.72 s and 3.46 ± 0.99 s in the angina group and control group respectively (p = 0.001). No significant differences were found between the groups with respect to TMP (p = 0.68) & cTIMI frame count (p = 0.22). CONCLUSION: CSFT is a simple method to assess the transit time through coronary microcirculation. CSFT was significantly delayed in patients with angina and normal coronaries. TMP and cTIMI frame count were not significantly different between groups.
No takes yet. Share an insight, caveat, or question.
Nandan et al. (2013) conducted an observational in Angina and normal coronaries (Syndrome X) (n=57). Angina and normal coronaries vs. Control group (undergoing coronary angiogram prior to balloon mitral valvuloplasty) was evaluated on Mean coronary sinus filling time (CSFT) in seconds (p=0.001). Coronary sinus filling time was significantly delayed in patients with angina and normal coronaries compared to controls (4.25 vs 3.46 seconds; p=0.001).
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: