Key result
Fetal LV global longitudinal strain fails to distinguish true aortic coarctation from false positives.
Why the study?
Prenatal identification of true aortic coarctation remains challenging due to high false-positive rates, and myocardial deformation has been proposed to improve prediction of postnatal outcome.
Does fetal myocardial deformation analysis using speckle-tracking echocardiography differentiate true aortic coarctation from false-positive cases in fetuses with suspected CoA?
Cohort (n=38)
Does fetal myocardial deformation analysis using speckle-tracking echocardiography differentiate true aortic coarctation from false-positive cases in fetuses with suspected CoA?
Absolute Event Rate: -20.1% vs -20.5%
p-value: p=0.57
Fetal myocardial deformation analysis does not provide additional predictive value over conventional cardiac dimensions for diagnosing true aortic coarctation postnatally.
Strain analysis adds no diagnostic value in suspected fetal coarctation; challenges deformation proposals and leaves open whether any advanced metrics improve accuracy.
Introduction: Prenatal identification of true aortic coarctation (CoA) remains challenging as evidenced by high false-positive rates. Myocardial deformation has been proposed to improve prediction of postnatal outcome. This prospective study aimed to determine whether fetal myocardial deformation analysis can differentiate true CoA from false-positive cases throughout gestation. Methods: All fetuses with a prenatal suspicion of isolated CoA were prospectively recruited at our fetal cardiology services. Cases were classified as true CoA or false-positives based on their postnatal diagnosis. Speckle-tracking echocardiography was performed longitudinally to assess left and right ventricular global longitudinal strain (GLS), strain rate, and segmental strain throughout gestation. Measurements were compared between true CoA and false-positive cases. Results: Thirty-eight fetuses were included (19 true CoA, 19 false-positives). True CoA cases exhibited smaller left-sided cardiac dimensions, including the aortic valve (mean Z-score −3.2 vs. −1.6, p<0.001), aortic isthmus (−3.5 vs. −1.7, p=0.001), and mitral valve (−4.9 vs. −3.1, p<0.001), whereas right-sided cardiac dimensions were comparable (pulmonary valve Z-score 3.0 vs. 2.6, p=0.64; arterial duct Z-score 1.9 vs. 3.2, p=0.61). No clinically relevant differences in myocardial deformation parameters were observed between groups, with similar left ventricular GLS (−20.1% vs. −20.5%, p=0.57), right ventricular GLS (−20.0% vs. −19.1%, p=0.13), strain rates and segmental strain. Conclusion: Fetal myocardial deformation analysis does not provide additional predictive value for postnatal outcome in prenatally suspected isolated CoA. Conventional assessment of cardiac dimensions and flow patterns remains the cornerstone of prenatal CoA diagnosis, yet current imaging modalities cannot provide sufficient diagnostic certainty to safely triage perinatal management.
No takes yet. Share an insight, caveat, or question.
Zwanenburg et al. (2026) conducted a cohort in Prenatally suspected isolated aortic coarctation (n=38). True aortic coarctation vs. False-positive cases was evaluated on Left ventricular global longitudinal strain (GLS) (p=0.57). Left ventricular global longitudinal strain did not significantly differ between fetuses with true aortic coarctation and false-positive cases (-20.1% vs -20.5%; P=0.57).
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: