Key result
Fetal CMR longitudinal strain fails to differentiate true coarctation from false positives in prenatal diagnosis.
Why the study?
Prenatal diagnosis of coarctation of the aorta is challenging with high false positive rates, and it was unknown if fetal CMR-derived ventricular strain could improve diagnostic accuracy.
Does fetal CMR-derived ventricular strain improve the prenatal diagnosis of true coarctation of the aorta compared to established echocardiographic markers in third-trimester fetuses?
Cohort (n=42)
No
Does fetal CMR-derived ventricular strain improve the prenatal diagnosis of true coarctation of the aorta compared to established echocardiographic markers in third-trimester fetuses?
Answers are grounded in this paper and cite their sources.
Fetal CMR-derived ventricular strain does not improve the prenatal diagnosis of coarctation of the aorta beyond established echocardiographic markers, and its values are highly dependent on analysis methodology.
Prenatal diagnosis of coarctation of the aorta (CoA) remains challenging, with low detection rates and high false positive rates. It is unknown whether fetuses that develop postnatal CoA (true CoA) exhibit impaired ventricular strain prenatally or whether fetal cardiac magnetic resonance (CMR)-derived strain can improve diagnostic accuracy. In addition, fetal strain assessment by CMR requires optimisation and validation. Forty-two third-trimester fetuses underwent fetal CMR at 1.5 T with Doppler ultrasound gating. Left and right ventricular four-chamber strain were assessed using feature tracking and endocardial shortening, respectively. Strain analysis was optimised by adjusting contour stiffness and tracking distance parameters and comparing results with myocardial centreline shortening. Fetal echocardiographic markers associated with true CoA were also evaluated, including the mitral-to-tricuspid valve ratio (MV/TV), aortic isthmus-to-duct ratio (I/D), the combined I/D × MV/TV ratio, and the carotid-subclavian artery index (CSAI). Strain analysis was feasible in 35 fetuses (9 true CoA, 18 false positives, and 8 controls). LV and RV strain values were significantly affected by optimization settings. Although fetuses with true CoA showed a tendency toward lower LV strain, no significant differences in LV or RV strain were observed between groups (all p > 0.05). In contrast, echocardiographic ratios differed between groups (all p < 0.05). Fetal CMR-derived strain is highly dependent on analysis methodology, and values obtained using different techniques are not interchangeable. While echocardiographic markers were associated with outcome, overlap between groups limits their predictive value. In its current form, fetal CMR-derived strain does not improve prenatal CoA diagnosis beyond established echocardiographic markers.
No takes yet. Share an insight, caveat, or question.
Fricke et al. (2026) conducted a cohort in Suspected coarctation of the aorta (n=42). Fetal CMR-derived longitudinal strain vs. False positive CoA and healthy controls was evaluated on Fetal CMR-derived longitudinal left ventricular strain (p=>0.05). Fetal CMR-derived longitudinal ventricular strain did not differ between fetuses with true coarctation of the aorta and false-positive cases, failing to improve prenatal diagnosis.