Key result
Bioresorbable MemoSorb occluder achieves complete PFO closure at 6 months in a pediatric case.
Why the study?
A bioresorbable PFO device was reported to close a patent foramen ovale in an asymptomatic pediatric diver with a phospholamban mutation while optimizing future transseptal access for potential hypertrophic cardiomyopathy.
Does transcatheter closure using a bioresorbable MemoSorb PFO Occluder safely and effectively achieve shunt closure in a pediatric diver with a patent foramen ovale and familial phospholamban mutation?
Case Report (n=1)
No
Does transcatheter closure using a bioresorbable MemoSorb PFO Occluder safely and effectively achieve shunt closure in a pediatric diver with a patent foramen ovale and familial phospholamban mutation?
Answers are grounded in this paper and cite their sources.
This case demonstrates the first successful off-label implantation of a bioresorbable MemoSorb PFO occluder in a pediatric diver with a phospholamban mutation, achieving complete shunt closure at 6 months while preserving future transseptal access.
We report biodegradable device implantation for primary prevention in an asymptomatic 11-year-old boy with a patent foramen ovale, normal biventricular function and phospholamban mutation, conferring an elevated future risk of hypertrophic cardiomyopathy. He was a keen diver, with ambitions to be a marine biologist. Following multidisciplinary discussion, closure of the defect was agreed, using a bioresorbable device to optimize future transseptal intervention for potential cardiomyopathy. A 34 mm Memosorb® PFO Occluder (Lepu medical Technology, Beijing, China) was positioned, complicated by complete atrioventricular block, regressing to first degree after removing the device. A 28mm device was then successfully implanted. Intermittent 2nd degree atrioventricular block occurred post-procedurally, treated with steroids, with normal holter ECG few weeks later. Bubble test echocardiography was negative after 6 months. The patient was allowed to dive again. The Memosorb ® biodegradable device can be implanted in selected cases. More studies are needed to confirm safety and efficacy.
No takes yet. Share an insight, caveat, or question.
Cooke et al. (2026) conducted a case report in Patent foramen ovale with familial hypertrophic cardiomyopathy and phospholamban mutation (n=1). MemoSorb bioresorbable PFO occluder device was evaluated on Complete PFO closure on bubble test echocardiography at 6 months. The 28 mm MemoSorb bioresorbable PFO occluder achieved complete PFO closure with a negative bubble test at 6 months in an 11-year-old boy after transient AV block resolved with steroids.