Key result
Baroreflex-based controller automatically detects optimal operating points for intra-aortic pumps in bench simulations.
Why the study?
It is important to find an optimum operating point for intra-aorta pumps that matches heart function and circulatory state in heart failure patients.
Left ventricular assist devices are increasingly used for long-term support in heart failure patients. It is important to find an optimum operating point for the pump that is appropriate for the existing function of the heart and the state of the circulatory system. Therefore, baroreflex sensitivity (BRS), as an indicator of heart function, is chosen as the control variable. In order to find an optimum point automatically, an extremum search algorithm (ESA) is designed to find an optimal mean arterial pressure (MAP), for which the BRS is maximum. Then, a MAP controller based on model-free adaptive control is designed to ensure that the measured MAP tracks the desired one. In order to test the feasibility of the control strategy, numerical simulations and simplified in vitro experiments were conducted. A mathematic model of the cardiovascular system simulating left ventricular failure, physical activity, and recovery of cardiac function is used in the simulation. The numerical simulations show that the maximum value of BRS can be found automatically by using ESA. The rotational speed of the pump is automatically increased (from 6500 rpm to 7000 rpm), and peripheral resistance is decreased to simulate slight physical activity. When E(max) is increased from 0.6 mm Hg/mL to 1.8 mm Hg/mL to mimic heart recovery, the speed is decreased from 7000 rpm to 6300 rpm in response. The optimum operating point for the pump can be detected by the proposed control strategy without the need to set a reference value for the control variable by operators.
No takes yet. Share an insight, caveat, or question.
Gao et al. (2012) studied Heart failure. Physiological controller of an intra-aorta pump based on baroreflex sensitivity using extremum search algorithm was evaluated on Detection of optimum operating point for the pump (optimal mean arterial pressure for maximum baroreflex sensitivity). A physiological controller based on baroreflex sensitivity successfully and automatically detected the optimum operating point for an intra-aorta pump in numerical and in vitro simulations.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: