Key result
Transcutaneous auricular vagus nerve stimulation acutely lowers spontaneous sequence baroreflex sensitivity by ~2 ms/mmHg.
Why the study?
Cardiovascular responses to transcutaneous auricular vagus nerve stimulation are heterogeneous and autonomic outcomes are not interchangeable, requiring exploratory evaluation.
Does acute transcutaneous auricular vagus nerve stimulation alter spontaneous sequence baroreflex sensitivity or Mayer-wave coherence in healthy men?
Does acute transcutaneous auricular vagus nerve stimulation alter spontaneous sequence baroreflex sensitivity or Mayer-wave coherence in healthy men?
In healthy men, acute transcutaneous auricular vagus nerve stimulation paradoxically lowered spontaneous baroreflex sensitivity and increased systolic blood pressure without altering Mayer-wave coherence, highlighting the complexity of autonomic responses to this intervention.
Answers are grounded in this paper and cite their sources.
Acute taVNS effects on baroreflex sensitivity should not guide practice; leaves open net autonomic impact in patients.
Transcutaneous auricular vagus nerve stimulation (taVNS) delivers afferent inputs, but cardiovascular responses are heterogeneous and autonomic outcomes are not interchangeable. In this exploratory, non-randomised, open-label study, 18 healthy men completed fixed-order five-minute Pre, left-cymba Stim, and Post phases without sham. Spontaneous sequence baroreflex sensitivity (BRS seq, all ; designated centrally post hoc) was lower during Stim than Pre (8.54 ± 5.57 versus 6.49 ± 3.89 ms/mmHg; paired mean difference − 2.05, BCa 95% CI − 3.81 to − 1.10; Wilcoxon p = 2.29 × 10 − 5 ; Cohen’s d z = − 0.74), with negative differences in 17/18 participants. Mayer-band coherence and representative heart rate variability indices showed no detectable Stim–Pre differences. Systolic blood pressure was higher during Stim. Recovery of BRS was not established. No adverse events were reported after the sessions. Sequence BRS estimates blood pressure–R–R interval gain, whereas heart rate variability and coherence quantify different properties. This pattern supports prospective evaluation of sequence BRS as a session-level physiological response measure. The design does not establish stimulation-specific engagement, direct vagal inhibition, clinical utility, or a monitoring threshold. Sham-controlled replication is required. Trial registration: Japan Registry of Clinical Trials (jRCT), jRCT1032230440. Registered on 9 November 2023.
No takes yet. Share an insight, caveat, or question.
Katahara et al. (2026) studied Healthy volunteers (n=18). Transcutaneous auricular vagus nerve stimulation (taVNS) vs. Pre-stimulation baseline was evaluated on Spontaneous sequence baroreflex sensitivity (BRSseq, all) (MD -2.05, 95% CI -3.81 to -1.10, p=2.29 × 10^-5). Transcutaneous auricular vagus nerve stimulation acutely lowered spontaneous sequence baroreflex sensitivity by a mean difference of 2.05 ms/mmHg compared to baseline.
Synapse has enriched 10 related papers. Consider them for comparative context: