Key result
Early NSVT on remote monitoring is linked to ~79% higher cardiovascular mortality in pacemaker patients.
Why the study?
The clinical value and prognostic significance of non-sustained ventricular tachycardia detected by remote interrogation in pacemaker patients is uncertain.
Cohort (n=408)
No
May flag higher CV mortality risk in pacemaker patients; hypothesis-generating and requires prospective validation before guiding interventions.
BACKGROUND: Non-sustained ventricular tachycardia (NSVT) can occur asymptomatically and can be incidentally detected in the internal records of pacemakers (PM). The clinical value of NSVT in the population of PM patients is still uncertain.Our aim was to assess the prevalence of NSVT detected by remote PM control, to describe the clinical and demographic characteristics of patients with NSVT, and to assess the prognostic significance of NSVT in terms of both overall and cardiovascular mortality. METHODS: Consecutive patients followed with PM remote interrogations from September 2010 to December 2015 were included. The transmissions pertaining to the first 12 months of remote control were analysed and the patients were divided by those presenting NSVT and those without NSVT. The two groups were compared in terms of total mortality and cardiovascular mortality based on the administrative data provided by the regional administration of the Italian National Health System. RESULTS: The prevalence of NSVT in 408 patients (62% males, mean age 75.6; SD 10.6 years old) was 21% in a year. During a mean follow-up duration of 44 months, NSVT did not emerge as independently associated with overall mortality, but was associated with cardiovascular mortality in a competing risk regression model with older age, male gender, diabetes, chronic renal insufficiency, ischemic cardiomyopathy and chronic obstructive pulmonary disease. CONCLUSIONS: We show that NSVT episodes recorded by remote control in a PM population are independently associated with cardiovascular mortality with possible implications for risk stratification and therapeutic options.
No takes yet. Share an insight, caveat, or question.
Poli et al. (2019) conducted a cohort in Patients with cardiac pacemakers (n=408). Non-sustained ventricular tachycardia (NSVT) detection vs. No NSVT detection was evaluated on Cardiovascular mortality (HR 1.792, 95% CI 1.007-3.189, p=0.047). In patients with pacemakers, the detection of non-sustained ventricular tachycardia during the first year of remote monitoring was independently associated with increased cardiovascular mortality (HR 1.792).
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: