Key result
≥50% RVP linked to ~352% higher NSVT risk without increasing mortality.
Why the study?
The incidence of ventricular arrhythmia in patients with an implanted pacemaker was not yet known.
Does ≥ 50% right ventricular pacing increase the risk of non-sustained ventricular tachycardia in patients with dual-chamber pacemakers?
Cohort (n=248)
No
Does ≥ 50% right ventricular pacing increase the risk of non-sustained ventricular tachycardia in patients with dual-chamber pacemakers?
Effect estimate: OR 4.519 (95% CI 2.480-8.237)
p-value: p=<0.001
In patients with dual-chamber pacemakers and preserved LVEF, ≥ 50% right ventricular pacing is an independent risk factor for NSVT, though this arrhythmia is not associated with increased all-cause mortality.
≥50% RV pacing was associated with NSVT but not mortality; hypothesis-generating and should not yet change pacing practice.
The incidence of ventricular arrhythmia in patients with an implanted pacemaker is not yet known. The aim of this study was to analyze non-sustained ventricular tachycardia (NSVT) episodes based on stored electrograms (EGM) and determine the occurrence rate and risk factors for NSVT in a pacemaker population.This study included 302 consecutive patients with a dual-chamber pacemaker. A total of 1024 EGMs stored in pacemakers as ventricular high-rate episodes were analyzed. The definition of NSVT was ≥ 5 consecutive ventricular beats at ≥ 150 bpm lasting < 30 seconds.In baseline, most patients (94.8%) had ≥ 60% left ventricular ejection fraction. Of 1024 EGMs, 420 (41.0%) showed appropriate NSVT episodes, as well as premature atrial contractions, atrial tachyarrhythmia, or atrial fibrillation with a rapid ventricular response, whereas other EGMs did not show an actual ventricular arrhythmia. On EGM analysis, during a mean follow-up period of 46.1 months, NSVT occurred one or more times in 82 patients (33.1%). On multivariate analysis, ≥ 50% right ventricular pacing was an independent risk factor for NSVT (odds ratios, 4.519; P < 0.001), but NSVT was not associated with increased all-cause mortality.Moreover, in the pacemaker population, ≥ 50% right ventricular pacing is an independent risk factor for NSVT; however, NSVT was not associated with increased all-cause mortality because of the preserved left ventricular function.
No takes yet. Share an insight, caveat, or question.
Hosoda et al. (2020) conducted a cohort in Patients with an implanted dual-chamber pacemaker (n=248). ≥50% right ventricular pacing vs. <50% right ventricular pacing was evaluated on Non-sustained ventricular tachycardia (NSVT) (OR 4.519, 95% CI 2.480-8.237, p=<0.001). In a pacemaker population, ≥50% right ventricular pacing was an independent risk factor for non-sustained ventricular tachycardia (OR 4.519), though it was not associated with increased mortality.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: