Key result
Transcatheter covered CP stenting successfully normalizes Qp/Qs to ~1.05 and resolves functional class III symptoms.
Why the study?
Superior sinus venosus atrial septal defects with partial anomalous pulmonary venous return typically require surgical repair because transcatheter-based interventions are limited by the lack of commercially available devices.
Does transcatheter repair using a custom 8-cm covered Cheatham-Platinum stent with a superior locking uncovered stent reduce left-to-right shunting and improve symptoms in an adult with superior SVASD and PAPVR?
Case Report (n=1)
No
Does transcatheter repair using a custom 8-cm covered Cheatham-Platinum stent with a superior locking uncovered stent reduce left-to-right shunting and improve symptoms in an adult with superior SVASD and PAPVR?
This case demonstrates that transcatheter closure of a complex superior SVASD with PAPVR in an adult is technically feasible and hemodynamically effective using a custom-manufactured 8-cm covered stent stabilized with a superior uncovered locking stent.
Answers are grounded in this paper and cite their sources.
May offer a nonsurgical option for select adults with superior SVASD and PAPVR; leaves open durability, safety, and generalizability.
BACKGROUND: Superior sinus venosus atrial septal defects (SVASDs) with partial anomalous pulmonary venous return (PAPVR) are complex interatrial communications typically requiring surgical repair. Transcatheter-based interventions are limited because of the lack of commercially available devices. CASE SUMMARY: of 1.05:1). DISCUSSION: Transcatheter closure of a superior SVASD with PAPVR in adults is technically feasible and favorable using custom-manufactured long devices. TAKE-HOME MESSAGE: Tailoring custom-manufactured devices to patient anatomy provides a novel approach to personalized medicine for percutaneous SVASD/PAPVR repair.
No takes yet. Share an insight, caveat, or question.
Mohtar et al. (2026) conducted a case report in Superior sinus venosus atrial septal defect (SVASD) with partial anomalous pulmonary venous return (PAPVR) (n=1). Transcatheter repair using a custom-made 10 Zig 8-cm covered Cheatham-Platinum (CP) stent with a superior locking 3110 Palmaz Genesis uncovered stent was evaluated on Reduction in pulmonary-to-systemic blood flow ratio (Qp/Qs). Transcatheter repair using a custom 8-cm covered CP stent and superior locking stent reduced the left-to-right shunt (Qp/Qs) from 1.8:1 to 1.05:1 and resolved functional class III symptoms by 4.5 months.
Synapse has enriched 10 related papers. Consider them for comparative context: