Key result
Extravascular ICD pneumopericardium transiently impairs sensing and defibrillation, resolving fully with conservative care.
Why the study?
Substernal tunneling for extravascular ICD implantation carries a risk of pericardial injury and pneumopericardium not encountered with transvenous systems.
Can conservative management with deferred defibrillation testing safely manage pneumopericardium complicating extravascular ICD implantation?
Case Report (n=1)
Can conservative management with deferred defibrillation testing safely manage pneumopericardium complicating extravascular ICD implantation?
Transient pneumopericardium during extravascular ICD implantation can temporarily impair sensing and defibrillation testing, but conservative management with deferred testing allows for safe resolution and avoids unnecessary device revisions.
BACKGROUND: Extravascular implantable cardioverter-defibrillators (EV-ICDs) use a substernal route to avoid intravascular lead placement, but substernal tunneling carries a risk of pericardial injury not encountered with transvenous systems. CASE SUMMARY: A 48-year-old man with ischemic cardiomyopathy (ejection fraction 14%) survived an out-of-hospital cardiac arrest due to monomorphic ventricular tachycardia at 240 beats/min. Cardiac magnetic resonance confirmed an extensive nonviable inferior scar. An EV-ICD was implanted for secondary prevention. Substernal tunneling was complicated by pericardial puncture and pneumopericardium. After lead repositioning, intraoperative defibrillation testing (DFT) failed twice, with subsequent sensing deterioration. Therapies were deactivated. Serial chest radiographs confirmed complete pneumopericardium resorption by day 30 with stable lead position. Repeat DFT at 5 weeks succeeded without reintervention. Device parameters remained normal at 1-year follow-up. DISCUSSION: Pneumopericardium is an under-recognized complication of substernal EV-ICD implantation that can transiently impair sensing and DFT. Conservative management with deferred re-testing illustrated a safe pathway, avoiding unnecessary system revisions.
No takes yet. Share an insight, caveat, or question.
Ollitrault et al. (2026) conducted a case report in Ischemic cardiomyopathy and out-of-hospital cardiac arrest (n=1). Extravascular implantable cardioverter-defibrillator (EV-ICD) implantation was evaluated. Extravascular ICD implantation was complicated by pneumopericardium, which transiently impaired sensing and defibrillation but resolved completely by day 30 with conservative management.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: