Key result
AI-synthesized 12-lead ECG from a wrist device detects acute MI with ~84% sensitivity.
Why the study?
The diagnostic value of a two-lead ECG acquired using a self-applicable, wrist-worn device for acute myocardial infarction detection was uncertain.
Does a two-lead wECG acquired via a wrist-worn device provide comparable diagnostic value to a standard 12-lead ECG for detecting acute myocardial infarction in adults?
Cross-Sectional (n=151)
Single-blind
No
Does a two-lead wECG acquired via a wrist-worn device provide comparable diagnostic value to a standard 12-lead ECG for detecting acute myocardial infarction in adults?
A two-lead wrist-worn ECG combined with neural network synthesis can detect acute myocardial infarction with sensitivity and specificity comparable to a standard 12-lead ECG, enabling potential out-of-hospital screening.
May support out-of-hospital AMI screening with wrist devices; leaves open prospective validation before clinical adoption.
Objective: To determine whether a two-lead ECG (wECG), acquired using a self-applicable, wrist-worn device, provides diagnostic value in acute myocardial infarction (AMI) detection. Methods: Seventy-one patients with AMI, 26 with other cardiovascular diseases (CVDs), and 54 healthy controls were enrolled in the study. To acquire lead I, one electrode of the wrist-worn device was touched with the index finger of the opposite hand, while another lead was acquired by touching the electrode on the strap to a specific part of the body. The diagnostic value of the wECG is evaluated either directly or through synthesis of the standard 12-lead ECG using an echo state network. Results: Using the standard ECG, an AMI detector based on a convolutional neural network yields a sensitivity of 0.86 and a specificity of 0.71; the corresponding figures for blinded cardiologist diagnosis are 0.77/0.88. Using the synthesized ECG, the V3 electrode touch site yields the best performance, with a sensitivity/specificity of 0.84/0.71 for AMI detection and 0.67/0.86 for cardiologist diagnosis. Compared to the synthesized ECG across all touch sites, use of the wECG results in a substantially lower sensitivity, reduced by 0.12–0.13, while the specificity is comparable or slightly higher. Implementation of a two-stage approach, consisting of detector-based screening followed by cardiologist review of positive cases, results in correct decisions in 63% of the AMI cases using either the synthesized ECG or the wECG. Conclusion: The two-lead ECG acquired with a wrist-worn device offers diagnostic value and enables screening for AMI.
No takes yet. Share an insight, caveat, or question.
Eitminaviciene et al. (2026) conducted a cross-sectional in Acute Myocardial Infarction (n=151). Two-lead wrist-worn ECG device (wECG) with 12-lead synthesis vs. Standard 12-lead ECG was evaluated on Sensitivity for acute myocardial infarction detection using a CNN-based detector (95% CI 0.83-0.86). A 12-lead ECG synthesized from a two-lead wrist-worn device yielded a sensitivity of 0.84 and specificity of 0.71 for automated acute myocardial infarction detection, comparable to a standard ECG.