Right axillary venous access enables successful coronary sinus reducer implantation after right internal jugular approach fails.
Why the study?
Right internal jugular access for coronary sinus reducer implantation can fail due to unfavorable catheter-coronary sinus ostium alignment, necessitating alternative access strategies.
Case Report
Right axillary venous access is an effective bailout strategy for coronary sinus reducer implantation when the conventional jugular approach fails.
Axillary access may enable coronary sinus reducer implantation after jugular failure; leaves open need for safety data in larger series.
OBJECTIVE: We describe right axillary venous access as a bailout strategy for coronary sinus reducer (CSR) implantation after failure of the conventional right internal jugular approach. KEY STEPS: Right jugular access failed because of unfavorable catheter-coronary sinus (CS) ostium alignment. Right axillary access using a 35° caudal projection provided a favorable trajectory. A Josephson catheter facilitated CS engagement, followed by 9-F guiding-catheter advancement using a mother-and-child technique and successful CSR deployment. POTENTIAL PITFALLS: Axillary puncture should avoid the lung field, and inadvertent arterial access must be excluded before sheath insertion. During the mother-and-child technique, excessive forward pressure may cause CS injury or perforation. Forceful contrast injection through a wedged catheter and inadequate support during device deployment should be avoided. TAKE-HOME MESSAGE: Axillary access may provide an effective bailout strategy for CSR implantation when conventional jugular access fails.
No takes yet. Share an insight, caveat, or question.
Costantino et al. (2026) conducted a case report in Coronary sinus reducer (CSR) implantation. Right axillary venous access vs. Conventional right internal jugular approach was evaluated on Successful CSR deployment. Right axillary venous access provided an effective bailout strategy for successful coronary sinus reducer implantation when the conventional right internal jugular approach failed.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: