Key result
Real-time 3D CMR-MOTUS accurately quantifies continuous beat-to-beat EF, capturing functional heterogeneity in arrhythmia.
Why the study?
Conventional CMR cine sequences average multiple heartbeats, causing motion artifacts and loss of functional information in arrhythmic patients, necessitating improved volumetric quantification methods.
Does 3D real-time CMR-MOTUS allow for accurate continuous beat-to-beat volumetric quantification in patients with premature ventricular contractions compared to standard 2D real-time cine?
Does 3D real-time CMR-MOTUS allow for accurate continuous beat-to-beat volumetric quantification in patients with premature ventricular contractions compared to standard 2D real-time cine?
Absolute Event Rate: 17.86% vs 17.27%
3D real-time CMR-MOTUS is a feasible method for continuous beat-to-beat ventricular volumetric quantification, uniquely capturing functional heterogeneity during arrhythmias that conventional averaging obscures.
May support ungated 3D EF quantification in arrhythmias; leaves open prospective validation before clinical adoption.
BACKGROUND: Conventional cardiovascular magnetic resonance (CMR) cine sequences rely on binning reconstructions that average multiple heartbeats, an assumption that breaks down in arrhythmic patients where beat-to-beat variations lead to motion artifacts and loss of clinically relevant functional information. While two-dimensional (2D) real-time imaging can capture individual heartbeats, a stack of 2D slices is sub-optimal to map the full complexity of incoherent cardiac dynamics during arrhythmia. We investigated the feasibility of three-dimensional (3D) real-time motion field reconstruction for continuous beat-to-beat volumetric quantification in patients with premature ventricular contractions (PVC) using a free-running CMR protocol. METHODS: We extended CMR-MOTUS to jointly reconstruct real-time 3D motion fields and a motion-corrected reference image from continuously acquired data without breath-holds or electrocardiogram (ECG) gating. A variable-density Cartesian sampling trajectory (OPRA) was used with a 3D spoiled gradient echo or balanced steady-state free precession sequence. The real-time volumetric beat-to-beat changes were quantified by propagating a single manual segmentation on the reference image, through all time frames using the reconstructed motion fields. The method was evaluated on a cardiac motion phantom with ground-truth static acquisitions and in 10 healthy volunteers and 10 patients with PVC. All in vivo datasets were acquired post contrast enhancement. The ejection fraction (EF) was compared to ground-truth values for the phantom and to standard 2D real-time cine EF measurement techniques for the in vivo subjects. RESULTS: Reconstructed mean EF values of the phantom experiment were close to the ground-truth (Mean EF = 17.86 ± 0.33% versus 17.27%). In healthy volunteers, narrow beat-to-beat EF distributions reflected normal physiological consistency. In PVC patients, the method revealed broader, sometimes bimodal EF distributions. Simultaneously acquired ECG signals supported the temporal correspondence between volume irregularities and PVC episodes. CONCLUSIONS: 3D real-time joint motion field and image reconstruction from a free-running CMR protocol enables continuous beat-to-beat volumetric quantification in arrhythmic patients, revealing functional heterogeneity that conventional single-beat and averaging measurements (binning and gating) can obscure. Larger studies are needed before claims of clinical validation or replacement of standard 2D cine analysis.
No takes yet. Share an insight, caveat, or question.
Olausson et al. (2026) studied Premature ventricular contraction (arrhythmia) (n=20). 3D real-time joint motion field and image reconstruction (CMR-MOTUS) vs. Standard 2D real-time cine MRI and ground-truth phantom was evaluated on Ejection fraction measurement accuracy (phantom). 3D real-time CMR-MOTUS enabled accurate continuous beat-to-beat volumetric quantification (phantom mean EF 17.86% vs 17.27% ground truth) and revealed functional heterogeneity in arrhythmic patients.