Key result
Real-time 3D echocardiography identifies anomalous papillary muscle insertion causing LVOT obstruction.
Why the study?
Anomalous insertion of the papillary muscle is a rare but important cause of dynamic LVOT obstruction that is challenging to diagnose with 2-D echocardiography yet critical for surgical planning.
Case Report (n=2)
Answers are grounded in this paper and cite their sources.
May aid diagnosis of rare papillary muscle anomalies in LVOT obstruction; hypothesis-generating pending larger validation.
Anomalous insertion of the papillary muscle (PM)/chordae tendineae is a rare but important cause of dynamic left ventricular outflow tract (LVOT) obstruction in patients with hypertrophic cardiomyopathy or cardiac amyloidosis. These anomalies are often challenging to diagnose with 2-D Echo, yet accurate diagnosis is critical in determining whether to proceed with an extended septal myectomy instead of a standard septal myectomy for relief. We report two cases of anomalous insertion of the PM causing LVOT obstruction with diagnosis facilitated by real-time 3-D echocardiograms.
No takes yet. Share an insight, caveat, or question.
Yang et al. (2008) conducted a case report in Anomalous insertion of the papillary muscle causing LVOT obstruction (n=2). Real-time three-dimensional echocardiography vs. 2-D Echo was evaluated. Real-time three-dimensional echocardiography facilitated the accurate diagnosis of anomalous insertion of the papillary muscle causing left ventricular outflow tract obstruction in two patients.