Answers are grounded in this paper and cite their sources.
HomeCirculation: Heart FailureVol. 11, No. 7The Luck of Having a Cardiac Implantable Electronic Device Free AccessEditorialPDF/EPUBAboutView PDFView EPUBSections ToolsAdd to favoritesDownload citationsTrack citationsPermissions ShareShare onFacebookTwitterLinked InMendeleyReddit Jump toFree AccessEditorialPDF/EPUBThe Luck of Having a Cardiac Implantable Electronic Device Maria Rosa Costanzo, MD Maria Rosa CostanzoMaria Rosa Costanzo Maria Rosa Costanzo, MD, Advocate Heart Institute, Edward Heart Hospital, 4th Floor, 801 S Washington St, PO Box 3226, Naperville, IL 60566. E-mail E-mail Address: [email protected] Advocate Heart Institute, Naperville, IL. Originally published12 Jul 2018https://doi.org/10.1161/CIRCHEARTFAILURE.118.004894Circulation: Heart Failure. 2018;11:e004894is related toHeartLogic Multisensor Algorithm Identifies Patients During Periods of Significantly Increased Risk of Heart Failure EventsSee Article by Gardner et alShallow men believe in luck or in circumstance.Strong men believe in cause and effect.—Ralph Waldo EmersonThe principle aims of the post hoc analysis by Gardner et al1 were to use data from the MultiSENSE study (Multisensor Chronic Evaluation in Ambulatory Heart Failure Patients) to further stratify the 1-year risk of heart failure events (HFE) based on different thresholds of the HeartLogic alert algorithm, compare their prognostic power to that of different NT-proBNP (N-terminal pro-B-type natriuretic peptide) levels, and assess whether the combination of algorithm and biomarker values stratified the risk of an HFE better than each measure alone.2 To develop the HeartLogic alert algorithm, data collected from multiple device sensors were used in combination with clinical baseline and HFE data. Initial analyses evaluated the performance of each sensor parameter to predict an HFE. Heart sounds (S1 and S3), thoracic impedance, respiration, heart rate, and activity emerged as variables detectable by device sensors that are predictive of an HFE. Changes in these features from each patient's baseline were aggregated and weighted based on an individual's daily risk for worsening HF. The HeartLogic index value is updated daily, and an alert is issued when the index crosses the nominal threshold of 16. In the MultiSENSE study, this alert index predicted the occurrence of HFE with a 70% sensitivity and a median of 34-day warning.2 The findings of the analysis by Gardner et al1 are undoubtedly impressive. Among 900 patients (average event rate: 0.20/patient-year), 145 HFE occurred over 1 year in 88 patients with evaluable HeartLogic alert algorithm. The risk of a HFE during periods in alert status was 10-fold that occurring during periods out of alert status (0.80 versus 0.08/patient-year).2 Substratification showed that, compared with the lowest risk group, defined as having low NT-proBNP and not in alert status, the highest risk group, identified by high NT-proBNP levels and being in alert status, had a 50-fold increased risk of an HFE (1.00/patient-year versus 0.02/patient-year).2 Importantly, atrial fibrillation and ischemic HF cause decreased, but did not eliminate the predictive power of the HeartLogic alert algorithm, underscoring its value across diverse subgroups of HF patients with LVEF ≤35% and implanted with a COGNIS (Boston Scientific, St. Paul, MN) cardiac resynchronization therapy-defibrillator device.2 In addition, although NT-proBNP levels had independent predictive power for HFE, it was significantly lower than that of the HeartLogic alert algorithm alone (event rates: 0.42 versus 0.80/patient-year). Furthermore, the risk for an HFE was greater in patients with low NT-proBNP levels but in HeartLogic alert status than in subjects with high NT-proBNP levels but out of device alert status (event rates: 0.47 versus 0.16/patient-year).2 These findings are reassuring, as it is neither practical nor recommended by US and European HF guidelines to serially assess biomarker levels and use them to guide therapy.3,4In addition to MultiSENSE, other studies have been conducted for risk stratification of HF patients based on combinations of data obtainable from cardiac implantable electronic devices (CIEDs); see Table. It is exceedingly difficult, if not altogether impossible, to meaningfully compare the performance of the various proposed indices as predictors of impending worsening HF: device, manufacturer, analytic methods, assessed parameters, end points, frequency of evaluation, type of risk stratification, length of follow-up, and results vary significantly between studies. However, all analyses have some aspects in common: (1) the relative weight of each measure in contributing to the final risk index cannot be determined. This is important because elevated values of a given index may lead to wrong therapeutic interventions without the knowledge of which variable(s) predominantly contributed to its elevation. Let us take for example a HeartLogic index rising above the nominal value of 16 primarily because of increased respiratory rate and rapid shallow breathing. In the absence of a position sensor, it is impossible to know whether the respiratory abnormality is because of paroxysmal nocturnal dyspnea from pulmonary edema or to sleep disorder breathing, conditions which require different interventions (diuretics versus polysomnogram-guided treatment of sleep apnea); (2) the extent to which changes in therapy occurring during both development and validation phases influenced the threshold of risk is unknown because the studies neither tracked nor standardized treatment approaches in their populations; (3) all indices were developed in HF patients with reduced LVEF who met criteria for CIEDs; and (4) none of the studies have yet demonstrated whether consistent treatment protocols targeting each specific risk index result in improvement of HF outcomes.2,5–7Table. Studies of Heart Failure Risk Stratification Using Variables From Cardiac Implantable Electronic Devices With 1-Year Follow-UpStudy (Sample Size)Study TypeBlindingVariables Evaluated in ScoreFrequency of EvaluationSelected OutcomesMultiSENSE; Boehmer et al2 (N=500/400)Multicenter, nonrandomizedInvestigators, Events comm.S1, S3, respiration, thoracic impedance, heart rate, activityDailyHFE detection; Sensitivity=70% [95% CI, 55.4–82.1]IN-TIME; Hindricks et al5 (N=333/331)Multicenter, randomizedNoneArrhythmias, %CRT, PVCs, activity, abnormal ICEDaily (working days)CCS (Algorithm vs SOC): 61 (18.9%) vs 90 (27.2%); P=0.013; Deaths: 10 vs 277 studies Cowie et al6 (N=921/1310)Combined analysisN/AThoracic impedance, AF burden, VRAF, VT, patient activity, heart rate, HRV, %CRTMonthlyHFH ↓; Hazard ratio, 10.0; 95% CI, 6.4–15.7; P<0.001PARTNERS HF; Whellan et al7 (N=694)Multicenter, observationalEvents comm.AF, ≥60 Ω Fluid Index, activity, night heart rate, HRV, device therapyMonthlyHFH ↓; Hazard ratio, 4.8; 95% CI, 2.9–8.1; P<0.0001AF indicates atrial fibrillation; CCS, clinical composite score; CI, confidence interval; comm., committee; CRT, cardiac resynchronization therapy; HF, heart failure; HFE, heart failure event; HFH, heart failure hospitalization; HRV, heart rate variability; ICE, intracardiac electrogram; IN-TIME, Implant-Based Multiparameter Telemonitoring of Patients With Heart Failure; MultiSENSE, Multisensor Chronic Evaluation in Ambulatory Heart Failure Patients; N/A, not applicable; PARTNERS-HF, Program to Access and Review Trending Information and Evaluate Correlation to Symptoms in Patients With Heart Failure; PVC, premature ventricular contractions; SOC, standard of care; VRAF, ventricular rate during atrial fibrillation; and VT, ventricular tachycardia.According to the 2017 American Heart Association Heart Disease and Stroke Statistics of an estimated 6.5 million Americans with symptomatic HF, 55% have HF with preserved LVEF. These patients account for 47% of >1 million annual hospital discharges for HF. The proportion of HF with preserved LVEF and their HFE rates are similar in Europe.4,8According to the IMPROVE HF (Registry to Improve the Use of Evidence-Based Heart Failure Therapies in the Outpatient Setting) among 167 cardiology practices in the United States, of patients eligible for cardiac resynchronization therapy or implantable cardioverter-defibrillator, only 38% and 49%, respectively, received the therapy.9The obvious consequence of these facts is that stratification of risk for HFE based on device data cannot be accomplished in a substantial proportion of the HF population.The advent of implantable hemodynamic sensors has greatly improved the understanding of hemodynamic congestion, the gradual transition to a decompensated HF state, identification of periods at risk for an HFE and opportunities for prevention of these events with the appropriate therapeutic interventions. The CHAMPION-HF trial (CardioMEMS [Cardio-Micro-ElectroMechanical Systems] Heart Sensor Allows Monitoring of Pressure to Improve Outcomes in Class III Heart Failure) showed that ambulatory monitoring of intracardiac pressures coupled with standardized pharmacological interventions resulted in a 39% decrease in HFE compared with standard of care over an average follow-up period of 15 months.10 The pharmacological algorithm used in the CHAMPION-HF trial recommended use of sequential doses of diuretics and vasodilators to reduce and maintain the pulmonary artery diastolic pressure <20 mm Hg.11 The therapeutic recommendations also provided guidance for reduction in diuretic and vasodilator doses if intracardiac filling pressures were low, to prevent hypovolemia and consequent hypotension-related increases in serum creatinine. With this approach, more than twice as many bidirectional medications changes occurred in the active monitoring group compared with controls without differences in estimated glomerular filtration rate between groups.11 Therefore, the observed decrease in HFE because of appropriate hemodynamic management was not achieved at the expense of worsening renal function, as seen in studies lacking objective therapeutic targets that can be easily and continuously tracked.11 The analysis of the stepped-up pharmacological algorithm and resulting changes in pulmonary artery pressures has completed the circle by linking reduction of elevated pulmonary artery pressures to reduced HFE through a more frequent adjustment of diuretics and vasodilators compared with changes triggered by clinical signs and symptoms alone. Moreover, the analysis demonstrates that specification of both the targets of therapeutic interventions and the algorithm which guides them is essential to validate any risk stratification method or novel management strategies.11 A recent analysis from the CHAMPION-HF trial showed that pulmonary artery pressure-guided HF management also reduces mortality in patients with HF with reduced LVEF who receive guideline-directed medical therapy, further highlighting the important synergy of addressing hemodynamic and neurohormonal targets of HF therapy.12 A separate analysis of the CHAMPION trial examined the impact of hemodynamically guided HF management in patients with LVEF ≥40%, the only prespecified subgroup of the study. After an average of 17-month randomized follow-up, patients in the active monitoring group had 50% less HFE than controls (hazard ratio, 0.50; 95% confidence interval, 0.35–0.70; P<0.0001). This analysis was one of the first to report a clinically successful medical management strategy in HF patients with LVEF ≥40%.13 The favorable outcomes of the CHAMPION trial are now being replicated and expanded in the real world, as shown by recent analyses from the CardioMEMS postapproval study.14,15The MultiSENSE study Investigators are correct in stating that the effective stratification of risk for HFE by the HeartLogic algorithm occurs in the context of commonly used CIEDs and does not introduce any additional risk from separate invasive procedures.2 However, the limitations of the HeartLogic algorithm must also be recognized, including inability to stratify the risk of HF patients with LVEF ≥35% and lack of treatment protocols aimed at specific targets. The upcoming MANAGE-HF trial (Multiple Cardiac Sensors for Management of Heart Failure; URL: http://www.clinicaltrials.gov. Unique identifier: NCT03237858) may help to optimize the clinical integration of the HeartLogic algorithm, but it will not address stratification of risk for HFE in patients lacking an indication for CIEDs.Ongoing research efforts are focused on the development of wearable devices that can detect CIED parameters such as those shown by MultiSENSE to accurately stratify the risk for HFE with enough warning to enable the timely implementation of therapies that can effectively prevent HF decompensation. Wearable devices do not require an invasive procedure and can be used in all HF patients, regardless of LVEF. As for CIED-derived risk indices, those arising from wearable devices must provide targets sufficiently specific to trigger the correct therapy.DisclosuresDr Costanzo receives consulting fees from Abbott, Medtronic, Boston Scientific, and Respicardia.FootnotesThe opinions expressed in this article are not necessarily those of the editors or of the American Heart Association.https://www.ahajournals.org/journal/circheartfailureMaria Rosa Costanzo, MD, Advocate Heart Institute, Edward Heart Hospital, 4th Floor, 801 S Washington St, PO Box 3226, Naperville, IL 60566. E-mail mariarosa.[email protected]comReferences1. Gardner RS, Singh JP, Stankak B, Nair DG, Cao M, Schulze C, Thakur PH, An Q, Wehrenberg S, Hammill EF, Zhang Y, Boehmer JP. The HeartLogic Multi-sensor algorithm identifies patients during periods of significantly increased risk of heart failure events: results from the MultiSENSE study.Circ Heart Fail. 2018; 11:e004669. doi: 10.1161/CIRCHEARTFAILURE.117.004669.LinkGoogle Scholar2. Boehmer JP, Hariharan R, Devecchi FG, Smith AL, Molon G, Capucci A, An Q, Averina V, Stolen CM, Thakur PH, Thompson JA, Wariar R, Zhang Y, Singh JP. A multisensor algorithm predicts heart failure events in patients with implanted devices: results from the MultiSENSE Study.JACC Heart Fail. 2017; 5:216–225. doi: 10.1016/j.jchf.2016.12.011.CrossrefMedlineGoogle Scholar3. Yancy CW, Jessup M, Bozkurt B, Butler J, Casey DE, Drazner MH, Fonarow GC, Geraci SA, Horwich T, Januzzi JL, Johnson MR, Kasper EK, Levy WC, Masoudi FA, McBride PE, McMurray JJ, Mitchell JE, Peterson PN, Riegel B, Sam F, Stevenson LW, Tang WH, Tsai EJ, Wilkoff BL; American College of Cardiology Foundation; American Heart Association Task Force on Practice Guidelines. 2013 ACCF/AHA guideline for the management of heart failure: a report of the American College of Cardiology Foundation/American Heart Association Task Force on Practice Guidelines.J Am Coll Cardiol. 2013; 62:e147–e239. doi: 10.1016/j.jacc.2013.05.019.CrossrefMedlineGoogle Scholar4. Ponikowski P, Voors AA, Anker SD, Bueno H, Cleland JGF, Coats AJS, Falk V, González-Juanatey JR, Harjola VP, Jankowska EA, Jessup M, Linde C, Nihoyannopoulos P, Parissis JT, Pieske B, Riley JP, Rosano GMC, Ruilope LM, Ruschitzka F, Rutten FH, van der Meer P; ESC Scientific Document Group. 2016 ESC Guidelines for the diagnosis and treatment of acute and chronic heart failure: the Task Force for the diagnosis and treatment of acute and chronic heart failure of the European Society of Cardiology (ESC)Developed with the special contribution of the Heart Failure Association (HFA) of the ESC.Eur Heart J. 2016; 37:2129–2200. doi: 10.1093/eurheartj/ehw128.CrossrefMedlineGoogle Scholar5. Hindricks G, Taborsky M, Glikson M, Heinrich U, Schumacher B, Katz A, Brachmann J, Lewalter T, Goette A, Block M, Kautzner J, Sack S, Husser D, Piorkowski C, Søgaard P; IN-TIME Study Group*. Implant-based multiparameter telemonitoring of patients with heart failure (IN-TIME): a randomised controlled trial.Lancet. 2014; 384:583–590. doi: 10.1016/S0140-6736(14)61176-4.CrossrefMedlineGoogle Scholar6. Cowie MR, Sarkar S, Koehler J, Whellan DJ, Crossley GH, Tang WH, Abraham WT, Sharma V, Santini M. Development and validation of an integrated diagnostic algorithm derived from parameters monitored in implantable devices for identifying patients at risk for heart failure hospitalization in an ambulatory setting.Eur Heart J. 2013; 34:2472–2480. doi: 10.1093/eurheartj/eht083.CrossrefMedlineGoogle Scholar7. Whellan DJ, Ousdigian KT, Al-Khatib SM, Pu W, Sarkar S, Porter CB, Pavri BB, O'Connor CM; PARTNERS Study Investigators. Combined heart failure device diagnostics identify patients at higher risk of subsequent heart failure hospitalizations: results from PARTNERS HF (Program to Access and Review Trending Information and Evaluate Correlation to Symptoms in Patients With Heart Failure) study.J Am Coll Cardiol. 2010; 55:1803–1810. doi: 10.1016/j.jacc.2009.11.089.MedlineGoogle Scholar8. Benjamin EJ, Blaha MJ, Chiuve SE, Cushman M, Das SR, Deo R, de Ferranti SD, Floyd J, Fornage M, Gillespie C, Isasi CR, Jiménez MC, Jordan LC, Judd SE, Lackland D, Lichtman JH, Lisabeth L, Liu S, Longenecker CT, Mackey RH, Matsushita K, Mozaffarian D, Mussolino ME, Nasir K, Neumar RW, Palaniappan L, Pandey DK, Thiagarajan RR, Reeves MJ, Ritchey M, Rodriguez CJ, Roth GA, Rosamond WD, Sasson C, Towfighi A, Tsao CW, Turner MB, Virani SS, Voeks JH, Willey JZ, Wilkins JT, Wu JH, Alger HM, Wong SS, Muntner P; American Heart Association Statistics Committee and Stroke Statistics Subcommittee. Heart disease and stroke statistics-2017 update: a report from the American Heart Association.Circulation. 2017; 135:e146–e603. doi: 10.1161/CIR.0000000000000485.LinkGoogle Scholar9. Fonarow GC, Albert NM, Curtis AB, Stough WG, Gheorghiade M, Heywood JT, McBride ML, Inge PJ, Mehra MR, O'Connor CM, Reynolds D, Walsh MN, Yancy CW. Improving evidence-based care for heart failure in outpatient cardiology practices: primary results of the Registry to Improve the Use of Evidence-Based Heart Failure Therapies in the Outpatient Setting (IMPROVE HF).Circulation. 2010; 122:585–596. doi: 10.1161/CIRCULATIONAHA.109.934471.LinkGoogle Scholar10. Abraham WT, Adamson PB, Bourge RC, Aaron MF, Costanzo MR, Stevenson LW, Strickland W, Neelagaru S, Raval N, Krueger S, Weiner S, Shavelle D, Jeffries B, Yadav JS; CHAMPION Trial Study Group. Wireless pulmonary artery haemodynamic monitoring in chronic heart failure: a randomised controlled trial.Lancet. 2011; 377:658–666. doi: 10.1016/S0140-6736(11)60101-3.CrossrefMedlineGoogle Scholar11. Costanzo MR, Stevenson LW, Adamson PB, Desai AS, Heywood JT, Bourge RC, Bauman J, Abraham WT. Interventions linked to decreased heart failure hospitalizations during ambulatory pulmonary artery pressure monitoring.JACC Heart Fail. 2016; 4:333–344. doi: 10.1016/j.jchf.2015.11.011.CrossrefMedlineGoogle Scholar12. Givertz MM, Stevenson LW, Costanzo MR, Bourge RC, Bauman JG, Ginn G, Abraham WT; CHAMPION Trial Investigators. Pulmonary artery pressure-guided management of patients with heart failure and reduced ejection fraction.J Am Coll Cardiol. 2017; 70:1875–1886. doi: 10.1016/j.jacc.2017.08.010.CrossrefMedlineGoogle Scholar13. Adamson PB, Abraham WT, Bourge RC, Costanzo MR, Hasan A, Yadav C, Henderson J, Cowart P, Stevenson LW. Wireless pulmonary artery pressure monitoring guides management to reduce decompensation in heart failure with preserved ejection fraction.Circ Heart Fail. 2014; 7:935–944. doi: 10.1161/CIRCHEARTFAILURE.113.001229.LinkGoogle Scholar14. Desai AS, Bhimaraj A, Bharmi R, Jermyn R, Bhatt K, Shavelle D, Redfield MM, Hull R, Pelzel J, Davis K, Dalal N, Adamson PB, Heywood JT. Ambulatory hemodynamic monitoring reduces heart failure hospitalizations in "Real-World" clinical practice.J Am Coll Cardiol. 2017; 69:2357–2365. doi: 10.1016/j.jacc.2017.03.009.CrossrefMedlineGoogle Scholar15. Heywood JT, Jermyn R, Shavelle D, Abraham WT, Bhimaraj A, Bhatt K, Sheikh F, Eichorn E, Lamba S, Bharmi R, Agarwal R, Kumar C, Stevenson LW. Impact of practice-based management of pulmonary artery pressures in 2000 patients implanted with the CardioMEMS sensor.Circulation. 2017; 135:1509–1517. doi: 10.1161/CIRCULATIONAHA.116.026184.LinkGoogle Scholar Previous Back to top Next FiguresReferencesRelatedDetailsCited By Costanzo M (2022) The Cardiorenal Syndrome in Heart Failure, Cardiology Clinics, 10.1016/j.ccl.2021.12.010, 40:2, (219-235), Online publication date: 1-May-2022. D'Onofrio A, Solimene F, Calò L, Calvi V, Viscusi M, Melissano D, Russo V, Rapacciuolo A, Campana A, Caravati F, Bonfanti P, Zanotto G, Gronda E, Vado A, Calzolari V, Botto G, Zecchin M, Bontempi L, Giacopelli D, Gargaro A and Padeletti L (2021) Combining home monitoring temporal trends from implanted defibrillators and baseline patient risk profile to predict heart failure hospitalizations: results from the SELENE HF study, EP Europace, 10.1093/europace/euab170, 24:2, (234-244), Online publication date: 2-Feb-2022. Costanzo M (2021) Methods to Assess Intra- and Extravascular Volume Status in Heart Failure Patients Textbook of Cardiorenal Medicine, 10.1007/978-3-030-57460-4_15, (177-206), . Costanzo M (2020) The Cardiorenal Syndrome in Heart Failure, Heart Failure Clinics, 10.1016/j.hfc.2019.08.010, 16:1, (81-97), Online publication date: 1-Jan-2020. Related articlesHeartLogic Multisensor Algorithm Identifies Patients During Periods of Significantly Increased Risk of Heart Failure EventsRoy S. Gardner, et al. Circulation: Heart Failure. 2018;11 July 2018Vol 11, Issue 7 Advertisement Article InformationMetrics © 2018 American Heart Association, Inc.https://doi.org/10.1161/CIRCHEARTFAILURE.118.004894PMID: 30002115 Originally publishedJuly 12, 2018 Keywordsheart ratealgorithmbiomarkerdyspneaheart failureEditorialsPDF Advertisement and Implantable Failure
No takes yet. Share an insight, caveat, or question.
Maria Rosa Costanzo (2018) conducted an editorial in Heart Failure (n=900). HeartLogic alert algorithm vs. Periods out of alert status was evaluated on Heart failure events.
Synapse has enriched 10 related papers. Consider them for comparative context: