Key result
Dual-source CT myocardial perfusion imaging identifies infarcted myocardium with ~0.85 AUC in preclinical model.
Why the study?
Myocardial ischemia–reperfusion injury and microvascular obstruction impair myocardial perfusion after acute myocardial infarction, but a reproducible large-animal model and evaluation by dual-source CT myocardial perfusion imaging were needed.
Does dual-source CT myocardial perfusion imaging (DSCT-MPI) accurately identify infarcted myocardium and microvascular obstruction in a large-animal model of ischemia-reperfusion injury?
Does dual-source CT myocardial perfusion imaging (DSCT-MPI) accurately identify infarcted myocardium and microvascular obstruction in a large-animal model of ischemia-reperfusion injury?
DSCT-MPI is capable of identifying both infarcted myocardium and non-infarcted hypoperfused regions consistent with distal microvascular obstruction in a post-reperfusion setting.
Answers are grounded in this paper and cite their sources.
DSCT-MPI detects infarcted myocardium in goat reperfusion injury; extends preclinical validation but leaves open clinical translation.
Background Myocardial ischemia–reperfusion injury (MIRI) contributes to adverse outcomes after acute myocardial infarction. Microvascular obstruction (MVO), a key component of MIRI, impairs myocardial perfusion despite successful epicardial revascularization. This study aimed to establish a reproducible large-animal model of embolization-induced MVO and evaluate myocardial perfusion heterogeneity using dual-source CT myocardial perfusion imaging (DSCT-MPI). Methods Eight male Saanen goats underwent 30 min of left circumflex artery occlusion followed by distal microcatheter injection of 20- μ m polystyrene microspheres to induce reperfusion-associated MVO. DSCT-MPI was performed immediately after model establishment, with myocardial perfusion assessed by iodine distribution. Pathology was evaluated using triphenyltetrazolium chloride and hematoxylin–eosin staining, and Bcl-2, Bax, and caspase-3 were quantified. Receiver operating characteristic (ROC) analysis was used to determine the iodine concentration threshold for infarcted myocardium. Results Seven of eight goats survived and underwent DSCT-MPI. Of 119 myocardial segments, 39 were infarcted, 14 were non-infarcted hypoperfused segments consistent with distal MVO, and 66 were normal. Binary ROC and diagnostic-performance analyses included the 39 infarcted and 66 normal segments, excluding the 14 MVO-consistent segments. At an iodine concentration cutoff of 1,582 μg/cm 3 , DSCT-MPI achieved 89.7% sensitivity, 90.9% specificity, and an AUC of 0.848 (95% CI, 0.736–0.959), with substantial histopathological agreement ( κ = 0.798). Infarcted myocardium showed reduced Bcl-2 and increased Bax and caspase-3 expression. The 14 hypoperfused segments without TTC-confirmed necrosis were classified as MVO-consistent rather than CMD. Conclusions A minimally invasive, reproducible goat model of embolization-induced myocardial reperfusion injury was established. DSCT-MPI identified infarcted myocardium and non-infarcted hypoperfused regions consistent with distal MVO, demonstrating post-reperfusion perfusion heterogeneity without supporting CMD. Because no direct CMR comparison was performed, these findings should be considered exploratory pathology-based validation.
No takes yet. Share an insight, caveat, or question.
Jin et al. (2026) studied Myocardial ischemia-reperfusion injury with microvascular obstruction (n=8). Dual-source computed tomography myocardial perfusion imaging (DSCT-MPI) vs. Histopathology (TTC and H&E staining) was evaluated on Diagnostic performance (AUC) of iodine concentration for identifying infarcted myocardium at the segment level (AUC 0.848, 95% CI 0.736-0.959). Dual-source computed tomography myocardial perfusion imaging identified infarcted myocardium with an AUC of 0.848 compared to histopathology in a goat model of reperfusion injury.
Synapse has enriched 10 related papers. Consider them for comparative context: