Key result
Novel PISA nomogram strongly correlates with planimetry for mitral valve area in mitral stenosis.
Why the study?
Although the accuracy of the proximal isovelocity surface area (PISA) method for mitral valve area measurement has been documented, it is not widely used clinically.
Cross-Sectional (n=23)
Answers are grounded in this paper and cite their sources.
Nomogram may aid PISA-based MVA measurement in mitral stenosis; hypothesis-generating and requires larger validation before adoption.
INTRODUCTION: Although its accuracy has been documented in many studies, the proximal isovelocity surface area (PISA) method is not used widely for mitral valve area (MVA) measurement. In this study, we prepared a new nomogram and tested its use in MVA assessment. MATERIAL AND METHODS: The study included 23 patients (age: 27 +/- 5 years) with mitral stenosis, of whom 7 were in atrial fibrillation. The MVA was measured by four methods: planimetry (PL) (reference method), pressure-half time (PHT), conventional PISA (CP), and nomogram (Nomo) methods. The nomogram included two unknowns: (1) r; the radius of the first PISA section; (2) a; the length of the border opposite to the PISA angle in the triangle with both adjacent borders of 1 cm. The nomogram was also tested for its popularity potential by eight echocardiographers, none of whom were included in the author list. RESULTS: Mean MVA(PL) was 1.85 +/- 0.53 cm(2) (range: 0.72-2.99), mean MVA(PHT) was 1.72 +/- 0.56 cm(2) (range: 0.91-3.30), mean MVA(CP) was 1.69 +/- 0.45 cm(2) (range: 0.97-2.54), and MVA(Nomo) was 1.70 +/- 0.44 cm(2) (0.96-2.49). The nomogram correlated with planimetry (r = 0.87; P < 0.001), pressure half-time (r = 0.71; P < 0.001) and conventional PISA (r = 0.99; P = 0.000) methods. The nomogram method also correlated with planimetry in patients with atrial fibrillation (r = 0.81; P = 0.026). The echocardiographers found that the nomogram is superior to the planimetry and conventional PISA methods but inferior to the pressure half-time method in terms of simplicity. CONCLUSION: The new nomogram is potentially helpful in measurement of MVA. It may be used as an additional method in assessing severity of mitral stenosis.
No takes yet. Share an insight, caveat, or question.
Uzun et al. (2007) conducted a cross-sectional in Mitral stenosis (n=23). Nomogram for proximal isovelocity surface area (PISA) method vs. Planimetry (reference), pressure-half time, and conventional PISA was evaluated on Correlation of mitral valve area measurement with reference planimetry (r = 0.87, p=<0.001). A new nomogram for the proximal isovelocity surface area method strongly correlated with reference planimetry for measuring mitral valve area in mitral stenosis.
Synapse has enriched 10 related papers. Consider them for comparative context: