Answers are grounded in this paper and cite their sources.
The number of chromosomal aberrations induced by a whole-body uniform exposure to ionizing radiation is typically assumed to follow a Poisson distribution. If this exposure is partial, the zero-inflated Poisson model is appropriate to describe the yield of chromosomal aberrations. In this work, two different Bayesian posterior approaches (numerical integration and Laplace’s approximation) for zero-inflated Poisson responses are studied for cytogenetic biodosimetry dose estimation purposes. They are evaluated using two experiments from the literature, both of which include data for dose–response calibration and the simulation of partial-body exposure. Laplace’s approximation demonstrates strong performance, delivering rapid results with a loss of precision that may not significantly impact clinical measurements compared to those obtained through the more computationally intensive numerical integration approach.
No takes yet. Share an insight, caveat, or question.
Higueras et al. (2025) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: