In this study, the fracture toughness KIC of high performance concrete (HPC) was determined by conducting three-point bending tests on eighty notched HPC beams of 500mm×100mm×100mm at high temperatures up to 450∘C (hot) and in cooled-down states (cold). When the concrete beams exposed to high temperatures for 16 hours, both thermal and hygric equilibriums were generally achieved. KIC for the hot concrete sustained a monotonic decrease tendency with the increasing temperature, with a sudden drop at 105∘C . For the cold concrete, KIC sustained a two-stage decrease trend, dropping slowly with the heating temperature up to 150∘C and rapidly thereafter. The fracture energy-based fracture toughness KIC ' was found to follow similar decrease trends with the heating temperature. The weight loss, the fracture energy and the modulus of rapture were also evaluated.