The 1-cycle SANEX process has been developed as a simplification of the DIAMEX+SANEX concept by reducing the required process steps from two to one. The goal is to separate americium(III) and curium(III) directly from a PUREX raffinate which is very complicated due to the complex composition of the solution. In previous work, extensive batch studies have been carried out using an organic phase comprising CyMe4-BTBP and TODGA. This system has now been further developed towards a counter-current centrifugal contactor test using a synthetic PUREX raffinate solution. Single stage experiments were carried out to study the extraction kinetics and a 32 stage flow-sheet is proposed with calculated recoveries for some key elements. The calculations show that americium is recovered in the product with only small amounts of impurities. A demonstration process following the designed flow-sheet is expected to fulfill all the requirements for this complicated separation.
No takes yet. Share an insight, caveat, or question.
Magnusson et al. (2012) studied this question.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: