Answers are grounded in this paper and cite their sources.
A compact and high-resolution fiber-optic refractive index (RI) sensor based on a microwave photonic filter (MPF) is proposed and experimentally validated. The sensing head utilizes a cascaded in-line interferometer fabricated by an input single-mode fiber (SMF) tapered fusion with no-core fiber-thin-core fiber (TCF)-SMF. The surrounding RI (SRI) can be demodulated by tracing the passband’s central frequency of the MPF, which is constructed by the cascaded in-line interferometer, electro-optic modulator, and a section of dispersion compensation fiber. The sensitivity of the sensor is tailorable through the use of different lengths of TCF. Experimental results reveal that with a 30 mm length of TCF, the sensor achieves a maximum theoretical sensitivity and resolution of −1.403 GHz/refractive index unit (RIU) and 1.425×10−7 RIU, respectively, which is at least 6.3 times higher than what has been reported previously. Furthermore, the sensor exhibits temperature-insensitive characteristics within the range of 25°C−75°C, with a temperature-induced frequency change of only ±1.5 MHz. This value is significantly lower than the frequency change induced by changes in the SRI. The proposed MPF-based cascaded in-line interferometer RI sensor possesses benefits such as easy manufacture, low cost, high resolution, and temperature insensitivity.
No takes yet. Share an insight, caveat, or question.
Cai et al. (2024) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: