Why the study?
Non-invasive imaging techniques allowing quantitative measurement of coronary artery morphology and function in living mice were lacking.
Does left main coronary artery blood flow peak and predominate during ventricular systole rather than diastole in conscious and anesthetized rats and mice?
Does left main coronary artery blood flow peak and predominate during ventricular systole rather than diastole in conscious and anesthetized rats and mice?
Answers are grounded in this paper and cite their sources.
This preclinical study challenges the long-standing physiological paradigm of diastolic-predominant coronary perfusion by demonstrating that left coronary blood flow in rats and mice peaks and predominates during ventricular systole in tight synchrony with aortic ejection.
Objectives This study aimed to establish non-invasive methods of assessing coronary artery morphology in normal and atherosclerotic mice in vivo. Background Coronary flow velocity reserve (CFVR) has been shown to correlate with coronary minimal lumen diameter (MLD) in patients with coronary artery stenosis. In mice, there are no existing non-invasive imaging techniques allowing quantitative measurement of the coronary artery morphology and function. Methods Systemic hemodynamic effects of adenosine were studied in seven C57BL/6 mice. In 17 C57BL/6 mice, CFVR was measured in the mid left coronary artery (LCA) using either hypoxia- or adenosine-induced coronary hyperemia. Further, in another 10 atherosclerotic low-density lipoprotein receptor (LDLR)-/- mice, the hypoxia-induced CFVR was performed and proximal LCA MLD was measured using ultrasound biomicroscopy (UBM). Histologic sections of the LCA were collected. Results The adenosine dose of 160 microg/kg/min induced maximal coronary hyperemia without any systemic hemodynamic effects. Adenosine and hypoxia-induced CFVR values averaged at 2.0 +/- 0.1 and 1.9 +/- 0.3, respectively, in C57BL/6 mice (p = NS). In LDLR-/- mice, CFVR and MLD ranged between 1.4 to 2.9 microm and 190 to 370 microm, respectively. Histology revealed proximal lumen-narrowing plaques in the LCA. Significant correlation was found between hypoxia-induced CFVR and the MLD (p < 0.005, R2 = 0.8707). Conclusions The CDE and UBM technique can be used to measure atherosclerosis-related lumen narrowing of the LCA in living mice. These non-invasive techniques may provide us with novel tools for following up disease status in mouse coronary arteries in a quantitative manner.
No takes yet. Share an insight, caveat, or question.
Wikström et al. (2005) studied Normal and atherosclerotic coronary circulation in small rodents (rats and mice) (n=31). Pulsed Doppler ultrasonic flow probe and high-resolution color Doppler echocardiography / ultrasound biomicroscopy vs. Ascending aortic flow timing and diastolic phase coronary flow was evaluated on Mean left main coronary artery volume blood flow during ventricular systole versus diastole in conscious rats (95% CI 10.7-17.8 vs 1.31-4.29, p=0.0074).
Synapse has enriched 10 related papers. Consider them for comparative context: