Key result
IVUS shows coronary compliance is ~45% lower in diseased segments and inversely tracks plaque area.
Why the study?
Intravascular ultrasound potentially enables in vivo evaluation of coronary artery compliance, and the determinants of coronary compliance in patients with coronary artery disease needed to be elucidated.
Cross-Sectional (n=27)
Effect estimate: r = -0.38 (plaque area)
Absolute Event Rate: 1.6% vs 2.9%
p-value: p=< 0.01
Intravascular ultrasound demonstrates that in vivo coronary artery compliance in patients with coronary artery disease decreases with age and is independently determined by arterial site as well as plaque presence, size, and calcification.
OBJECTIVES: The aim of this study was to elucidate determinants of coronary compliance in patients with coronary artery disease. BACKGROUND: Intravascular ultrasound potentially enables in vivo evaluation of coronary artery compliance. METHODS: Twenty-seven patients (mean age [+/- SD] 57 +/- 11 years, three women) undergoing coronary angioplasty were studied with intravascular ultrasound imaging. A mechanical intravascular ultrasound system (4.8F, 20 MHz) was used. A total of 58 different coronary segments (proximal to the target angiographic lesion) were studied. Of these, 35 were located in the left anterior descending, 9 in the left main, 8 in the left circumflex and 6 in the right coronary arteries. During intravascular ultrasound imaging, 22 segments (38%) appeared normal, but 36 (62%) had plaque (24 fibrotic, 3 lipidic and 9 calcified). Systolic-diastolic changes in area (delta A) and pressure (delta P) with respect to vessel area (A) were used to study normalized compliance (Normalized compliance = [delta A/A]/delta P [mm Hg-1 x 10(3)]). RESULTS: Lumen area and plaque area were 12.6 +/- 5.7 and 3 +/- 3 min2, respectively. Plaque was concentric (more than two quadrants) at 10 sites, but the remaining 26 plaques were eccentric. Compliance was inversely related to age (r = -0.34, p < 0.05) but was not related to other clinical variables. Compliance was greater in the left main coronary artery (3.9 +/- 2.1 vs. 1.8 +/- 1.2 mm Hg-1, p < 0.05) and in coronary segments with normal findings on ultrasound imaging (2.9 +/- 1.9 vs. 1.6 +/- 1.1 mm Hg-1, p < 0.01). Moreover, at diseased coronary segments compliance was lower in calcified plaques than in other types of plaques (1.2 +/- 0.7 vs. 2.3 +/- 1.6 mm Hg-1, p < 0.01) but was similar in concentric and eccentric plaques (1.6 +/- 1.5 vs. 1.6 +/- 0.9 mm Hg-1). Plaque area (r = -0.38, p < 0.01) was inversely correlated with compliance. On multivariate analysis, only age and plaque area were independently related to compliance. CONCLUSIONS: Intravascular ultrasound may be used to evaluate compliance in patients with coronary artery disease. Compliance is reduced with increasing age and is mainly determined by the arterial site and by the presence, size and characteristics of plaque on intravascular ultrasound imaging.
No takes yet. Share an insight, caveat, or question.
Alfonso et al. (1994) conducted a cross-sectional in Coronary artery disease (n=27). Coronary plaque on intravascular ultrasound (36 diseased segments) vs. Normal coronary segments on intravascular ultrasound (22 normal segments) was evaluated on Normalized coronary artery compliance ([delta A/A]/delta P [mm Hg-1 x 10(3)]) (r = -0.38 (plaque area), p=< 0.01). Intravascular ultrasound showed lower coronary compliance in diseased vs normal segments (1.6 vs 2.9 mm Hg-1, p<0.01), inversely correlating with plaque area (r=-0.38, p<0.01) and age (r=-0.34, p<0.05).