Key result
IVUS correlates closely with angiography for lumen diameter in concentric CAD, but less in eccentric lesions.
Why the study?
Angiography provides only a silhouette of the vessel lumen despite complex and eccentric CAD, and few data existed regarding intravascular ultrasound in patients with CAD, with no data available for subjects with normal coronaries.
Does intravascular ultrasound safely provide accurate luminal measurements and detailed wall morphology compared to angiography in normal subjects and patients with coronary artery disease?
Observational (n=51)
Does intravascular ultrasound safely provide accurate luminal measurements and detailed wall morphology compared to angiography in normal subjects and patients with coronary artery disease?
Answers are grounded in this paper and cite their sources.
Intravascular ultrasound is a safe and feasible in vivo technique that provides detailed images of normal and atherosclerotic coronary wall morphology while offering tomographic lumen measurements that correlate with angiography, though with notable differences in eccentric lesions.
BACKGROUND: Necropsy studies demonstrate that coronary artery disease (CAD) is frequently complex and eccentric. However, angiography provides only a silhouette of the vessel lumen. Intravascular ultrasound is a new tomographic imaging method for evaluation of coronary dimensions and wall morphology. Few data exist regarding intravascular ultrasound in patients with CAD, and no data exist for subjects with normal coronaries. METHODS AND RESULTS: We used a multielement 5.5F, 20-MHz ultrasound catheter to examine eight normal subjects and 43 patients with CAD. We assessed the safety of coronary ultrasound and the effect of vessel eccentricity on comparison of minimum luminal diameter by angiography and ultrasound. Normal and atherosclerotic wall morphology and stenosis severity were also evaluated by intravascular ultrasound. The only untoward effect was transient coronary spasm in five patients. At 33 sites in normal subjects, the lumen was nearly circular, yielding a close correlation between angiographic and ultrasonic minimum diameter (r = 0.92). At 90 sites in patients with CAD, ultrasound demonstrated a concentric cross section; correlation was also close (r = 0.93). However, at 72 eccentric sites, correlation was not as close (r = 0.77). For 41 stenoses, correlation between angiography and ultrasound for area reduction was moderate (r = 0.63). In normal subjects, wall morphology revealed a thin (0.30 mm or less) intimal leading edge and subadjacent sonolucent zone (0.20 mm or less). Patients with CAD exhibited increased thickness and echogenicity of the leading edge, thickened sonolucent zones, and/or attenuation of ultrasound transmission. CONCLUSIONS: These data establish that intravascular ultrasound is feasible and safe and yields luminal measurements that correlate generally with angiography. Differences between angiographic and ultrasound measures of lumen size in eccentric vessels probably reflect the dissimilar perspectives of tomographic and silhouette imaging techniques. Intravascular ultrasound provides detailed images of normal and abnormal wall morphology not previously possible in vivo.
No takes yet. Share an insight, caveat, or question.
Nissen et al. (1991) conducted an observational in Coronary artery disease (n=51). Intravascular ultrasound (5.5F, 20-MHz catheter) vs. Coronary angiography was evaluated on Correlation between angiographic and ultrasonic minimum luminal diameter and wall morphology assessment (r = 0.92 (normal), r = 0.93 (concentric CAD), r = 0.77 (eccentric CAD)). Intravascular ultrasound correlated closely with angiography for minimum luminal diameter in normal and concentric CAD sites, but less so in eccentric sites.
Synapse has enriched 10 related papers. Consider them for comparative context: