Key result
Dynamic 11C-acetate PET correlates strongly with cardiac MRI for measuring LV mass and volumes.
Why the study?
Dynamic cardiac PET measurements of left ventricular mass and volume typically require electrocardiogram-gated data, and the feasibility of measuring LV geometry using nongated dynamic cardiac PET was unexplored.
Observational (n=45)
May allow nongated PET LV geometry assessment; hypothesis-generating and needs CMR validation before adoption.
UNLABELLED: Dynamic cardiac PET is used to quantify molecular processes in vivo. However, measurements of left ventricular (LV) mass and volume require electrocardiogram-gated PET data. The aim of this study was to explore the feasibility of measuring LV geometry using nongated dynamic cardiac PET. METHODS: Thirty-five patients with aortic-valve stenosis and 10 healthy controls underwent a 27-min (11)C-acetate PET/CT scan and cardiac MRI (CMR). The controls were scanned twice to assess repeatability. Parametric images of uptake rate K1 and the blood pool were generated from nongated dynamic data. Using software-based structure recognition, the LV wall was automatically segmented from K1 images to derive functional assessments of LV mass (mLV) and wall thickness. End-systolic and end-diastolic volumes were calculated using blood pool images and applied to obtain stroke volume and LV ejection fraction (LVEF). PET measurements were compared with CMR. RESULTS: High, linear correlations were found for LV mass (r = 0.95), end-systolic volume (r = 0.93), and end-diastolic volume (r = 0.90), and slightly lower correlations were found for stroke volume (r = 0.74), LVEF (r = 0.81), and thickness (r = 0.78). Bland-Altman analyses showed significant differences for mLV and thickness only and an overestimation for LVEF at lower values. Intra- and interobserver correlations were greater than 0.95 for all PET measurements. PET repeatability accuracy in the controls was comparable to CMR. CONCLUSION: LV mass and volume are accurately and automatically generated from dynamic (11)C-acetate PET without electrocardiogram gating. This method can be incorporated in a standard routine without any additional workload and can, in theory, be extended to other PET tracers.
No takes yet. Share an insight, caveat, or question.
Harms et al. (2016) conducted an observational in Aortic-valve stenosis and healthy controls (n=45). Nongated dynamic 11C-acetate PET vs. Cardiac MRI (CMR) was evaluated on Correlation of LV mass, end-systolic volume, and end-diastolic volume with CMR (r = 0.95 (LV mass), r = 0.93 (ESV), r = 0.90 (EDV)). Nongated dynamic 11C-acetate PET correlated highly with cardiac MRI for measuring LV mass (r=0.95), end-systolic volume (r=0.93), and end-diastolic volume (r=0.90).
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: