Answers are grounded in this paper and cite their sources.
We report on a strain sensing approach that relies on monitoring the mechanical resonant frequency of a suspended, double-clamped, stretched optical fiber with an inscribed Bragg grating (FBG). This resonant frequency, which varies with strain, is measured using the FBG. A reduced-order model of the fiber-beam is used to estimate the expected frequency shift Δf=f−f0, with respect to an unstretched fiber frequency f0, and to determine appropriate design and operating parameters. Using a custom-built setup that provides controlled fiber stretching and excitation by an external shaker, frequency sensing in the kHz range is experimentally demonstrated. The FBG measurements using the slope-assisted interrogation technique are validated by simultaneously detecting the fiber’s time-domain response with a laser Doppler vibrometer (LDV). Consistently with the model prediction, an experimental frequency–strain scale factor of Δf/ε≈5.6Hz/με is obtained. The corresponding normalized sensitivity, (Δf/f0)/ε≈682, is more than two orders of magnitude higher than that obtained by direct FBG strain measurement. This resonance-based approach also retains the potential for multiplexed sensing at multiple locations along a single fiber. The applicability of the technique to resonant vibrating-beam accelerometers is demonstrated using the model.
No takes yet. Share an insight, caveat, or question.
Ashkenazy et al. (2026) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: