Key result
Circulating secretoneurin did not predict ventricular arrhythmias (HR 1.3; 95% CI 0.8-2.1; p=0.3), but predicted mortality (HR 7.0; p<0.001) and HF hospitalizations (HR 4.6; p<0.001).
Why the study?
Secretoneurin provides strong prognostic information in acute and chronic HF, but whether circulating secretoneurin concentrations predict mortality in stable outpatients with ICDs, and whether risk relates to HF worsening or ventricular arrhythmias, were unknown.
Does circulating secretoneurin concentration predict incident ventricular arrhythmias, mortality, and heart failure hospitalizations in stable outpatients with an implantable cardioverter-defibrillator?
Cohort (n=489)
Yes
Does circulating secretoneurin concentration predict incident ventricular arrhythmias, mortality, and heart failure hospitalizations in stable outpatients with an implantable cardioverter-defibrillator?
In stable outpatients with ICDs, circulating secretoneurin concentrations strongly predict mortality and heart failure hospitalizations, but do not predict incident ventricular arrhythmias.
Secretoneurin should not guide arrhythmia risk stratification in ICD patients; extends HF prognostic data but remains hypothesis-generating.
Background Secretoneurin (SN) is a biomarker that provides strong prognostic information in patients with acute and chronic heart failure (HF). Whether SN concentrations predict mortality in stable outpatients with implantable cardioverter-defibrillators (ICDs), and whether potential increased risk relates to HF worsening or ventricular arrhythmias, are not known. Purpose To examine whether circulating SN concentrations can predict incident ventricular arrhythmias (primary endpoint) and mortality and HF hospitalizations (secondary endpoints) in high-risk outpatients with ICD. Methods We included 489 stable patients treated with ICD for both primary and secondary prevention from the outpatient service of two academic centers in Norway. SN concentrations were measured with prototype research-use only automated SN chemiluminescence immunoassay. We defined ventricular arrhythmia as either ventricular fibrillation or sustained ventricular tachycardia >100 b.p.m for minimum 30 sec, or appropriately delivered ICD therapies, i.e. electrical shock or anti-tachycardia pacing. Information regarding HF hospitalizations and mortality was obtained by review of electronic medical records. Results Median SN concentration was 33 pmol/L (quartile 1-3 26-41 pmol/L) and patients with high SN concentrations had higher prevalence of several risk factors, lower body mass index (BMI), and lower estimated glomerular filtration rate (eGFR) (Table). During mean follow-up 3.1±0.7 years, 136 patients (28%) experienced ventricular arrhythmia, 86 patients (18%) were hospitalized for HF, and 76 patients (16%) died. SN concentrations were associated with HF hospitalizations (hazard ratio [log] SN 4.6 [95% confidence interval 2.8-7.6], p<0.001) and mortality (hazard ratio 7.0 [4.2-11.5], p<0.001), but not with ventricular arrhythmia (hazard ratio 1.3 [0.8-2.1], p=0.3). The associations between SN quartiles and HF hospitalizations and mortality are presented in the Figure. Adjusting for age, sex, BMI, history of coronary artery disease and HF, and left ventricular ejection fraction (LVEF), SN concentrations (log transformed) were associated with HF hospitalization (hazard ratio 3.6 [1.8-7.3], p<0.001) and mortality (hazard ratio 4.7 [2.2-9.9], p<0.001). Adjusting also for eGFR, SN concentrations were still significantly associated with mortality and borderline significant for HF hospitalizations (p=0.07). Conclusion SN concentrations measured in stable ICD outpatients predict mortality and HF hospitalizations during follow-up, but not incident arrhythmic events. Accordingly, SN seems to provide strong prognostic information in stable outpatients with ICD, and more linked to HF worsening than to incident ventricular arrhythmia.
No takes yet. Share an insight, caveat, or question.
Rosjo et al. (2026) conducted a cohort in Stable outpatients with implantable cardioverter-defibrillators (ICDs) (n=489). Circulating secretoneurin (SN) concentrations vs. Lower secretoneurin concentrations / quartiles was evaluated on Incident ventricular arrhythmias (ventricular fibrillation, sustained ventricular tachycardia >100 bpm for ≥30 sec, or appropriate ICD therapy) (HR 1.3, 95% CI 0.8-2.1, p=0.3). Circulating secretoneurin did not predict ventricular arrhythmias (HR 1.3; 95% CI 0.8-2.1; p=0.3), but predicted mortality (HR 7.0; p<0.001) and HF hospitalizations (HR 4.6; p<0.001).
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: