Key result
Elevated secretoneurin is linked to ~70% higher all-cause mortality in patients hospitalized with acute dyspnea.
Why the study?
High-throughput assays are needed for novel biomarkers to have clinical utility, but the performance of a new high-throughput secretoneurin assay was unknown.
Does Secretoneurin measured by a high-throughput CLIA assay correlate with ELISA and predict mortality in patients hospitalized with acute dyspnea?
Cohort (n=299)
Does Secretoneurin measured by a high-throughput CLIA assay correlate with ELISA and predict mortality in patients hospitalized with acute dyspnea?
Effect estimate: HR 1.7 (95% CI 1.1-2.7)
A novel high-throughput secretoneurin CLIA assay correlates well with standard ELISA and provides independent prognostic information for mortality in patients with acute dyspnea.
Does not support routine secretoneurin testing in acute dyspnea; leaves open incremental value beyond NT-proBNP and troponin in prospective studies.
BACKGROUND: High-throughput assays are required for novel biomarkers to have clinical potential. Secretoneurin (SN) is a candidate biomarker, and the performance of a new high-throughput SN assay is not known. METHODS: We measured SN concentrations with a prototype chemiluminescent immunoassay (CLIA) in 299 patients hospitalized with acute dyspnea. We compared the results with a CE-marked SN enzyme linked immunosorbent assay (ELISA). We adjudicated the cause of dyspnea as heart failure (HF) or non-HF, and we obtained information on all-cause mortality during follow-up. RESULTS: SN concentrations measured with CLIA and ELISA were closely correlated: rho = 0.81, P < 0.001. SN CLIA concentrations were higher in HF patients (n = 129) compared to patients with non-HF-related dyspnea (n = 170): median 51 (quartile 1-3 40-69) vs 41 (32-54) pmol/L, P < 0.001. The area under the curve (AUC) of SN CLIA to diagnose HF was 0.64 (95% CI, 0.58-0.71) and the AUC of N-terminal pro-B-type natriuretic peptide (NT-proBNP) was 0.85 (0.81-0.89). During median 818 days follow-up, 110 patients died (37%). There was a nonlinear association between SN CLIA concentrations and mortality with optimal cutpoint 53 pmol/L. SN CLIA concentrations >53 pmol/L were associated with mortality after adjusting for clinical variables and NT-proBNP and cardiac troponin T concentrations: hazard ratio 1.7 (95% CI, 1.1-2.7), AUC 0.67 (0.61-0.74). We found similar results for SN ELISA for diagnosis and prognosis with AUC 0.63 (0.57-0.70) for the prediction of mortality. CONCLUSION: The high-throughput SN CLIA correlates with the SN ELISA and provides independent prognostic information over established biomarkers in patients with acute dyspnea.
No takes yet. Share an insight, caveat, or question.
Røsjø et al. (2025) conducted a cohort in Acute dyspnea (n=299). Secretoneurin (SN) chemiluminescent immunoassay (CLIA) vs. SN ELISA and NT-proBNP was evaluated on All-cause mortality (HR 1.7, 95% CI 1.1-2.7). Secretoneurin CLIA concentrations >53 pmol/L were associated with increased all-cause mortality in patients hospitalized with acute dyspnea (HR 1.7; 95% CI 1.1-2.7).
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: