Key result
Pulsed field ablation with left atrial ICE resulted in a 14.2% incidence of persistent iatrogenic atrial septal defect at 1 year, with no closures required.
Why the study?
Real-world data on the incidence, characteristics, and clinical implications of persistent iatrogenic atrial septal defect after pulsed field ablation for AF using left atrial intracardiac echocardiography remain limited.
What is the incidence, characteristics, and clinical significance of persistent iatrogenic atrial septal defect (iASD) at one year following pulsed field ablation (PFA) with left atrial intracardiac echocardiography (LA ICE) in patients with atrial fibrillation?
Cohort (n=772)
No
What is the incidence, characteristics, and clinical significance of persistent iatrogenic atrial septal defect (iASD) at one year following pulsed field ablation (PFA) with left atrial intracardiac echocardiography (LA ICE) in patients with atrial fibrillation?
Answers are grounded in this paper and cite their sources.
Pulsed field ablation guided by left atrial intracardiac echocardiography via a single transseptal puncture has a 14.2% rate of persistent iASD at one year, though none resulted in paradoxical embolism, right heart dilation, or need for closure.
Background Pulsed field ablation (PFA) has become a preferred modality for atrial fibrillation (AF) ablation because of its myocardial selectivity and lower collateral injury risk. Iatrogenic atrial septal defect (iASD) remains a consideration during transseptal access, particularly when left atrial intracardiac echocardiography (LA ICE) is used. Most defects are small, hemodynamically insignificant, and close spontaneously; however, real-world data on persistent iASD after PFA with LA ICE remain limited. Objective To assess the incidence, characteristics, and clinical implications of persistent iASD after PFA using LA ICE. Methods We performed a prospective imaging analysis of patients who underwent PFA for AF with LA ICE using a single transseptal puncture. Baseline echocardiograms were compared with one-year follow-up studies to determine iASD persistence, and patients were monitored for related symptoms or complications. Results A total of 772 patients (mean age 72 ± 12 years; 52% male) underwent PFA with LA ICE using 10– 14F transseptal sheaths and 8–10F ICE catheters. At one year, persistent iASD was identified in 14.2%, all showing left-to-right shunting; 10.1% were small (<3 mm) and hemodynamically insignificant, while 4.1% were moderate. No patient developed right-sided dilation, paradoxical embolism, or required closure. Migraine symptoms occurred in 1.2%, resolving by six months in most; four had symptoms at one year. Patients with persistent iASD had longer septal dwell time (52 ± 12 vs. 31 ± 11 min), greater use of larger-diameter sheaths, higher LA pressure (28 ± 4 vs. 12 ± 3 mmHg), and lower LVEF (32 ± 11% vs. 54 ± 14%). They were slightly younger (69 ± 9 vs. 71 ± 11 years) and more often female (65% vs. 52%). Conclusion PFA with LA ICE is associated with a low rate of clinically significant persistent iASD. Risk appears influenced by sex, sheath size, LA dwell time, and LA pressure. Continued follow-up and multicenter validation are needed as LA ICE–guided PFA workflows evolve.iASD TableiASD chart
No takes yet. Share an insight, caveat, or question.
Mraiyan et al. (2026) conducted a cohort in Atrial fibrillation (n=772). Pulsed field ablation with left atrial intracardiac echocardiography was evaluated on Persistent iatrogenic atrial septal defect at 1 year. Pulsed field ablation with left atrial ICE resulted in a 14.2% incidence of persistent iatrogenic atrial septal defect at 1 year, with no closures required.