Key result
Higher post-TAVR transmitral gradient is linked to ~13% higher late mortality per 1 mmHg.
Why the study?
Risk stratification after TAVR focuses largely on aortic valve performance and baseline clinical characteristics, while the prognostic relevance of residual transmitral haemodynamics after TAVR is uncertain.
Does higher post-TAVR transmitral mean pressure gradient (TMPG) and its periprocedural change (ΔTMPG) predict late all-cause mortality in patients undergoing TAVR?
Cohort (n=849)
Does higher post-TAVR transmitral mean pressure gradient (TMPG) and its periprocedural change (ΔTMPG) predict late all-cause mortality in patients undergoing TAVR?
Residual transmitral haemodynamic burden (higher post-TAVR TMPG and increasing ΔTMPG) is independently associated with late all-cause mortality after TAVR and may help refine post-procedural risk stratification.
Answers are grounded in this paper and cite their sources.
May inform post-TAVR risk stratification with elevated TMPG; leaves open whether gradient mitigation improves survival.
Background Risk stratification after transcatheter aortic valve replacement (TAVR) focuses largely on aortic valve performance and baseline clinical characteristics. The prognostic relevance of residual transmitral haemodynamics after TAVR is uncertain. Purpose To assess whether post-TAVR transmitral mean pressure gradient (TMPG) and its periprocedural change (ΔTMPG) are associated with late mortality. Methods Consecutive patients undergoing TAVR with paired pre- and post-procedural transthoracic echocardiography were analysed. Post-TAVR TMPG was measured on the first post-discharge study (1–6 months) and analysed both continuously and categorically (≥5 mmHg). ΔTMPG was defined as post- minus pre-TAVR TMPG. The primary endpoint was all-cause mortality during follow-up. Associations were evaluated using Cox proportional hazards models adjusted for predefined baseline clinical variables. Results Among 849 patients (median age 81 years; 47% women), over a median follow-up of 4.6 years, 322 deaths occurred. Higher post-TAVR TMPG was independently associated with late mortality (adjusted hazard ratio [HR] per 1 mmHg increase 1.13, 95% confidence interval [CI] 1.08–1.19; p<0.001). A TMPG ≥5 mmHg was associated with increased mortality (HR 1.87, 95% CI 1.43–2.44; p<0.001). Increasing ΔTMPG was also independently associated with mortality (HR per 1 mmHg increase 1.15, 95% CI 1.07–1.23; p<0.001). Conclusion Residual transmitral haemodynamic burden after TAVR is independently associated with mortality and may inform post-procedural risk assessment.
No takes yet. Share an insight, caveat, or question.
Cohen et al. (2026) conducted a cohort in Aortic stenosis treated with transcatheter aortic valve replacement (TAVR) (n=849). Post-TAVR transmitral mean pressure gradient (TMPG) vs. Lower post-TAVR TMPG (<5 mmHg or per 1 mmHg decrease) was evaluated on All-cause mortality during follow-up (HR 1.13, 95% CI 1.08-1.19, p=<0.001). Higher post-TAVR transmitral mean pressure gradient was independently associated with increased late all-cause mortality.
Synapse has enriched 10 related papers. Consider them for comparative context: