Key result
Immediate heart-rate rise >=10 bpm after CNM plus PVI linked to ~28-point lower AF recurrence.
Why the study?
Predictors of AF recurrence and the durability of autonomic response after cardiac neuromodulation combined with pulmonary vein isolation remain uncertain.
Does an immediate stable heart-rate rise after combined cardiac neuromodulation and pulmonary vein isolation reduce atrial fibrillation recurrence in patients with paroxysmal atrial fibrillation and profound resting sinus bradycardia?
Cohort (n=33)
Does an immediate stable heart-rate rise after combined cardiac neuromodulation and pulmonary vein isolation reduce atrial fibrillation recurrence in patients with paroxysmal atrial fibrillation and profound resting sinus bradycardia?
Answers are grounded in this paper and cite their sources.
In patients with paroxysmal atrial fibrillation and profound sinus bradycardia undergoing combined pulmonary vein isolation and cardiac neuromodulation, an acute post-procedural heart-rate increase of ≥10 bpm is a safe and significant predictor of lower arrhythmia recurrence.
Introduction Cardiac neuromodulation (CNM) aims to rebalance cardiac autonomic tone by targeting atrial ganglionated plexi. Predictors of atrial fibrillation (AF) recurrence and the durability of autonomic response after CNM combined with pulmonary vein isolation remain uncertain. Purpose To identify predictors of AF recurrence and to test the hypothesis that an immediate stable heart-rate (HR) rise after CNM is associated with lower recurrence in patients with paroxysmal AF and profound resting sinus bradycardia. Methods We conducted a retrospective study of 33 consecutive patients who underwent combined CNM + pulmonary veins isolation for AF (2019–2025). Baseline comorbidities, medications and symptoms were recorded. Primary endpoint was AF recurrence documented by ECG or ambulatory monitoring. Immediate autonomic response was predefined as a stable HR rise >10 bpm between the last pre-ablation and first post-ablation measurements. Comparisons used t-tests or Fisher’s exact test, as appropriate. Missing data were analysed as observed without imputation. Results Mean age was 59.8 ± 12.5 years and 51.5% were male. Hypertension 63.6%, dyslipidaemia 51.5%, diabetes 12.1%. Palpitations were present in 88%. The mean number of ablated plexi at first procedure was 2.44 ± 1.22. Patients with recurrence were younger (52.8 ± 15.2 vs 61.6 ± 10.8 years; one-sided p = 0.047, Figure 1). No major complications occurred during the procedures. An immediate HR rise ≥ 10 bpm occurred in 22/33 (66.7%) and was associated with a lower AF recurrence rate (27% vs 55%; p = 0.03, Figure 2). Neither classic left atrium high-rate stimulation, vagal extracardiac stimulation, nor targeting ≥3 versus ≤2 plexuses were associated with AF recurrence on univariate testing (all p > 0.10). No major procedural complications occurred. Conclusion(s) In this study, CNM was safe and produced measurable autonomic modulation in 2/3 of patients, captured by an immediate stable HR rise >10 bpm. AF recurrence was not linked to most baseline or procedural variables, but younger age and the absence of acute HR rise emerged as marker of higher recurrence risk. Validation in larger, prospective cohorts with systematic HR variability acquisition and predefined procedural endpoints are needed to refine candidate selection and optimise CNM durability.
No takes yet. Share an insight, caveat, or question.
Constantino et al. (2026) conducted a cohort in Paroxysmal atrial fibrillation and profound resting sinus bradycardia (n=33). Immediate stable heart-rate rise >=10 bpm after combined cardiac neuromodulation and pulmonary vein isolation vs. Absence of immediate heart-rate rise >=10 bpm was evaluated on Atrial fibrillation recurrence documented by ECG or ambulatory monitoring (p=0.03). An immediate heart-rate rise >=10 bpm after cardioneuromodulation plus PVI was associated with lower AF recurrence vs no rise.
Synapse has enriched 10 related papers. Consider them for comparative context: