Key result
Visual estimation of neonatal ventricular function shows limited quantitative concordance except in severe LV dysfunction.
Why the study?
Neonatologist-performed echocardiography (NPE) operators typically visually estimate systolic function and confirm it with quantitative markers when indicated, making it necessary to evaluate the concordance between qualitative and quantitative echocardiographic markers among NPE and non-NPE operators.
Does qualitative visual estimation of biventricular systolic function correlate with quantitative echocardiographic markers when assessed by NPE and non-NPE operators in newborn infants?
Cohort (n=60)
Blinded
Yes
Does qualitative visual estimation of biventricular systolic function correlate with quantitative echocardiographic markers when assessed by NPE and non-NPE operators in newborn infants?
Visual estimation on neonatal echocardiography can rapidly identify severe ventricular dysfunction at the bedside, but objective quantitative parameters are necessary to reliably detect mild-to-moderate dysfunction.
Visual estimation may aid rapid bedside detection of severe neonatal LV dysfunction; leaves open reliability for milder cases and requires prospective validation.
Background Neonatologist-performed echocardiography (NPE) is increasingly practiced. NPE operators typically use visual estimation of systolic function and, if indicated, confirm function using quantitative echocardiographic markers. This exploratory study aims to compare the concordance between qualitative and quantitative echocardiographic markers among NPE and non-NPE operators. Methods We studied a cohort of newborn infants, undergoing routine NPE by the authors at Homerton University Hospital and Aberdeen Maternity Hospital from April 2024 to October 2024. Blinded NPE and non-NPE operators independently assessed left and right ventricular systolic function visually. We compared visual estimation with standard quantitative echocardiographic markers such as shortening fraction, Simpson’s ejection fraction and global longitudinal strain for left ventricle and tricuspid annular plane systolic excursion and fractional area change for right ventricle. We examined the concordance between visual estimation and quantitative echocardiographic markers for biventricular systolic function. Results Sixty infants with a mean (SD) gestation and birth weight of 34 (6.2) weeks and 2311 (1319) grams respectively were examined. Sensitivity testing for all echocardiographic parameters ranged from 25% to 80% whereas specificity ranged from 38% to 78%. Sensitivity increased with worsening grades of LV dysfunction defined using shortening fraction. While concordance between NPE and non-NPE operator was generally limited across most echocardiographic parameters, test-retest reliability was acceptable for several quantitative measures, including Simpson’s ejection fraction, global longitudinal strain and right ventricular fractional area change. Conclusion Visual estimation may be a useful bedside tool for detecting severe ventricular dysfunction in newborn infants; however; quantitative echocardiographic measures are likely to improve the assessment of mild to moderate dysfunction. Further studies should confirm these findings in a larger cohort with a higher representation of infants with ventricular dysfunction.
No takes yet. Share an insight, caveat, or question.
Pereira et al. (2026) conducted a cohort in Ventricular systolic dysfunction assessment in newborn infants (n=60). Visual estimation of biventricular systolic function by NPE and non-NPE operators vs. Quantitative echocardiographic markers (shortening fraction, Simpson's biplane ejection fraction, global longitudinal strain, TAPSE, and fractional area change) was evaluated on Concordance (Cohen's Kappa) and diagnostic accuracy (sensitivity and specificity) between visual estimation and quantitative echocardiographic markers for biventricular systolic function. Visual estimation of neonatal ventricular systolic function showed limited concordance with quantitative markers overall (sensitivity 25-80%, specificity 38-78%), though sensitivity reached 100% for severe LV dysfunction.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: