Key result
AI-assisted echocardiography detects LVSD with ~82% sensitivity and ~89% specificity vs. standard imaging.
Why the study?
AI-assisted echocardiography has been proposed to improve reproducibility and efficiency in assessing LVSD, but reported diagnostic performance remains heterogeneous.
Does AI-assisted transthoracic echocardiography accurately detect left ventricular systolic dysfunction compared to expert human-interpreted TTE or cardiac MRI in adults?
Meta-Analysis (n=2,397)
Does AI-assisted transthoracic echocardiography accurately detect left ventricular systolic dysfunction compared to expert human-interpreted TTE or cardiac MRI in adults?
AI-assisted echocardiography demonstrates high sensitivity and specificity comparable to expert human interpretation for detecting left ventricular systolic dysfunction, supporting its use as a diagnostic adjunct in high-throughput or resource-limited clinical settings.
AI-assisted TTE offers reliable detection of LV systolic dysfunction; confirms pooled accuracy across studies and supports adjunctive use in high-throughput settings.
Background Accurate assessment of left ventricular systolic dysfunction (LVSD) is central to cardiovascular diagnosis and management. Artificial intelligence (AI)–assisted echocardiography has been proposed to improve reproducibility and efficiency, but reported diagnostic performance remains heterogeneous. Objective To systematically evaluate the diagnostic accuracy of AI-assisted transthoracic echocardiography (TTE) for detecting LVSD. Methods A systematic review and diagnostic test accuracy meta-analysis was conducted in accordance with PRISMA-DTA guidelines and registered on PROSPERO. MEDLINE, Embase, and trial registers were searched for studies evaluating convolutional neural network–based echocardiographic systems in adults. The index test was AI-assisted echocardiography, and reference standards included expert human-interpreted TTE or cardiac magnetic resonance imaging. Risk of bias was assessed using QUADAS-2. Pooled sensitivity and specificity were estimated using a bivariate random-effects model. Prespecified sensitivity analyses restricted inclusion to cart-based TTE studies and to studies using a left ventricular ejection fraction (LVEF) threshold <50%. Results Seven studies comprising 2,397 participants met inclusion criteria. Two studies evaluated handheld point-of-care ultrasound and five evaluated cart-based TTE. Using a bivariate random-effects model, pooled sensitivity was 0.82 (95% CI 0.73–0.89) and pooled specificity was 0.89 (95% CI 0.82–0.93). Restriction to cart-based TTE yielded pooled sensitivity of 0.80 (95% CI 0.67–0.89) and specificity of 0.91 (95% CI 0.83–0.95). Restriction to studies using an LVEF <50% threshold increased pooled sensitivity to 0.85 (95% CI 0.75–0.91). Risk of bias was generally low, with some concerns related to patient selection. Conclusions AI-assisted echocardiography demonstrates high diagnostic accuracy for detecting LVSD, comparable to expert interpretation. These findings support its role as a diagnostic adjunct, particularly in high-throughput and resource-limited settings.
No takes yet. Share an insight, caveat, or question.
Browne et al. (2026) conducted a meta-analysis in Left ventricular systolic dysfunction (LVSD) (n=2,397). AI-assisted transthoracic echocardiography (TTE) vs. Expert human-interpreted TTE or cardiac magnetic resonance imaging was evaluated on Diagnostic accuracy (pooled sensitivity and specificity) for detecting left ventricular systolic dysfunction (Sensitivity 0.82, Specificity 0.89, 95% CI Sensitivity 0.73-0.89, Specificity 0.82-0.93). AI-assisted echocardiography detected LVSD with a pooled sensitivity of 0.82 (95% CI 0.73-0.89) and specificity of 0.89 (95% CI 0.82-0.93) compared to expert TTE or cardiac MRI.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: