Key result
Seven-hour PAC monitoring identifies excessive supraventricular ectopy with ~94% sensitivity.
Why the study?
Prior studies defined excessive supraventricular ectopy using 24-hours or 48-hours of ECG monitoring and thresholds of ≥720 PACs/24 hours, leaving it uncertain whether shorter monitoring durations would suffice to identify most patients meeting this criterion.
Does shorter duration ECG monitoring (e.g., 1 to 7 hours using a threshold of ≥30 PACs/hour) accurately identify ≥720 PACs/24 hours in patients aged ≥60 years with recent ischemic stroke and no prior atrial fibrillation?
RCT (n=5,231)
Randomized
Yes
Does shorter duration ECG monitoring (e.g., 1 to 7 hours using a threshold of ≥30 PACs/hour) accurately identify ≥720 PACs/24 hours in patients aged ≥60 years with recent ischemic stroke and no prior atrial fibrillation?
Short ECG monitoring of 1 to 7 hours using an hourly threshold of ≥30 PACs accurately identifies acute ischemic stroke patients with high daily PAC burden, enabling early risk stratification for prolonged ECG monitoring.
Answers are grounded in this paper and cite their sources.
May support abbreviated ECG monitoring to flag high PAC burden post-stroke; hypothesis-generating for AF risk stratification in prospective trials.
Background An increased number of premature atrial contractions (PACs) has been associated with an increased risk of atrial fibrillation (AF) and ischemic stroke. Prior studies used 24-hours or 48-hours of ECG monitoring and thresholds of ≥720 PACs/24 hours to define excessive supraventricular ectopy (ESVEA). Purpose To determine whether shorter durations of ECG monitoring (e.g. one hour) would suffice to identify most patients who have ≥720 PACs/24 hours. Methods FIND-AF 2 is a multicenter trial including patients ≥60 years with recent ischemic stroke and no prior AF. Patients are randomized to enhanced, prolonged and intensified ECG monitoring or usual care. All patients received a 24-hours Holter-ECG prior to randomization to exclude AF and to quantify the number of PACs. In this analysis, 5,231 patients with complete 24-hours Holter-ECGs and without AF were evaluated. Holter-ECGs were divided into hourly intervals. PAC positivity was defined as ≥30 PACs in at least one hour. The ≥720 PAC/24 hours criterion served as reference standard. Sensitivity, specificity, and the Youden index were calculated across cumulative monitoring durations. Distributional analyses were performed among PAC-positive recordings. Results A total of 1,054 recordings met the ≥720 PAC/24 hours criterion. Overall, 2,147 Holter-ECGs were classified as PAC-positive. Among PAC-positive recordings, patients with ≥720 PAC/24 hours exhibited a substantially higher number of hours with ≥30 PACs compared with <720 PAC/24 hours (median 17 vs 2 hours, p<0.001), demonstrating near-complete separation of distributions (Figure 1). After 1 hour, the ≥30 PAC threshold showed high specificity (96%) and moderate sensitivity (70%) for identifying ≥720 PAC/24 hours. Sensitivity increased while specificity declined with longer monitoring, with optimal discrimination after 7 hours (Youden index 0.801; sensitivity 94%, specificity 86%) (Figure 2). Conclusion High daily PAC burden reflects sustained hourly PAC activity rather than isolated peaks. A single-hour threshold provides a highly specific early rule-in approach, while 7-hour monitoring achieves optimal balance. Short ECG monitoring for a few hours may be used to risk-stratify ischemic stroke patients for prolonged ECG monitoring.
No takes yet. Share an insight, caveat, or question.
Richter et al. (2026) conducted an RCT in Acute ischemic stroke without prior atrial fibrillation (n=5,231). Short-duration hourly ECG monitoring (≥30 PACs/hour threshold) vs. 24-hour Holter-ECG (≥720 PACs/24 hours reference standard) was evaluated on Identification of excessive supraventricular ectopy (≥720 PACs/24 hours) (Youden index 0.801 (at 7 hours; sensitivity 94%, specificity 86%), p=<0.001). Hourly PAC monitoring (≥30 PACs/h) identified ≥720 PACs/24h with 96% specificity and 70% sensitivity after 1 hour, and 94% sensitivity and 86% specificity after 7 hours.
Synapse has enriched 10 related papers. Consider them for comparative context: